Simultaneous quantification of tegoprazan and its major metabolite M1 in dog plasma using liquid chromatography-tandem mass spectrometry.
Kim, Joohwan; Kim, Sungjun; Noh, Hyun-Jung; Ryu, Shin-Young; Kim, Soo-Jin.
Afiliação
  • Kim J; CJ Healthcare Corporation, Deokpyeong-ro 811, Majang-myeon, Icheon-si, Gyeonggi-do, 17389, Republic of Korea.
  • Kim S; CJ Healthcare Corporation, Pine Avenue A-dong, 6/7/8F, Eulji-ro 100, Jung-gu, Seoul, 04551, Republic of Korea.
  • Noh HJ; CJ Healthcare Corporation, Deokpyeong-ro 811, Majang-myeon, Icheon-si, Gyeonggi-do, 17389, Republic of Korea.
  • Ryu SY; CJ Healthcare Corporation, Deokpyeong-ro 811, Majang-myeon, Icheon-si, Gyeonggi-do, 17389, Republic of Korea. Electronic address: shinyoung.ryu@kolmar.co.kr.
  • Kim SJ; CJ Healthcare Corporation, Deokpyeong-ro 811, Majang-myeon, Icheon-si, Gyeonggi-do, 17389, Republic of Korea. Electronic address: soojin.kim8@kolmar.co.kr.
J Pharm Biomed Anal ; 171: 99-103, 2019 Jul 15.
Article em En | MEDLINE | ID: mdl-30981194
ABSTRACT
Tegoprazan is a novel potassium-competitive acid blocker (P-CAB) recently approved in Korea as a next-generation therapeutics for gastric acid-related diseases. In the present study, we demonstrate a simple bioanalytical liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of tegoprazan and its major metabolite (M1) in dog plasma. The developed method is based on protein precipitation and LC-MS/MS, validated according to the regulatory guidance for bioanalytical method validation. The calibration curves were linear in the concentration range of 50 ng/mL-50 µg/mL and 5 ng/mL-5 µg/mL for tegoprazan and M1, respectively. The inter- and intra-day precisions were evaluated with a coefficient of variation of <15%, and the mean accuracy ranged 92.6%-105%. The method exhibited good sensitivity and specificity. The stability of bench-top (for 8 h), freeze-thaw (3 cycles), and processed-samples (for 24 h at 4 °C) was acceptable. Tegoprazan was stable in dog plasma for 6 weeks at -70 °C. In conclusion, we successfully established a method for the simultaneous quantification of tegoprazan and M1 in dog plasma, and the method was validated for specificity, sensitivity, linearity, matrix effects, recovery, accuracy, precision, and stability. Finally, we show that the method was successfully applied to a pharmacokinetic study in dogs.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Derivados de Benzeno / Cromatografia Líquida / Espectrometria de Massas em Tandem / Imidazóis / Antiácidos Tipo de estudo: Diagnostic_studies / Guideline Limite: Animals País/Região como assunto: Asia Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Derivados de Benzeno / Cromatografia Líquida / Espectrometria de Massas em Tandem / Imidazóis / Antiácidos Tipo de estudo: Diagnostic_studies / Guideline Limite: Animals País/Região como assunto: Asia Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2019 Tipo de documento: Article