Your browser doesn't support javascript.
loading
PRELIMINARY TECHNICAL DISCUSSION ON A NEW RADON AND ITS PROGENY CONTINUOUS MONITOR USING TWO-FILTER METHOD.
Igarashi, Yu; Nozaki, Takahiro; Mizuno, Hiroyuki; Kuroki, Tomohiro; Uchida, Yuki; Janik, Miroslaw; Iimoto, Takeshi.
Afiliação
  • Igarashi Y; Department of Environment Systems, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa-City, Chiba, Japan.
  • Nozaki T; Fuji Electric Co., Ltd., Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, Japan.
  • Mizuno H; Fuji Electric Co., Ltd., Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, Japan.
  • Kuroki T; Fuji Electric Co., Ltd., Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, Japan.
  • Uchida Y; National Institutes for Quantum and Radiological Sciences and Technology, National Institute of Radiological Science, 4-9-1 Anagawa, Inage-ku, Chiba-City, Chiba, Japan.
  • Janik M; National Institutes for Quantum and Radiological Sciences and Technology, National Institute of Radiological Science, 4-9-1 Anagawa, Inage-ku, Chiba-City, Chiba, Japan.
  • Iimoto T; Department of Environment Systems, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa-City, Chiba, Japan.
Radiat Prot Dosimetry ; 184(3-4): 418-421, 2019 Oct 01.
Article em En | MEDLINE | ID: mdl-31038709
Focusing on the scalability of Two-Filter Method, we started to develop a monitor for the concentration of radon and its progeny. In this study, we investigated the influence of a high-humidity environment on measuring radon concentration, and the influence of the decay chamber of the monitor on the measurement. In the high-humidity test, the conversion factor of (Bqm-3)/(cpm) tends to raise with increasing humidity. On the measurement of radon progeny, existence of the decay chamber of the monitor makes measurement sensitivity lower under environments of little aerosols. Radon concentration measurement by the developed monitor could be influenced by environmental humidity, and that counting loss could occur due to deposition of radon progeny inside of the decay chamber. Correction relating these would be needed based on the data of calibration tests.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Monitoramento de Radiação / Radônio / Produtos de Decaimento de Radônio / Aerossóis / Poluentes Radioativos do Ar Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Monitoramento de Radiação / Radônio / Produtos de Decaimento de Radônio / Aerossóis / Poluentes Radioativos do Ar Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão