Your browser doesn't support javascript.
loading
Adaptive cardiac resynchronization therapy is associated with decreased risk of incident atrial fibrillation compared to standard biventricular pacing: A real-world analysis of 37,450 patients followed by remote monitoring.
Hsu, Jonathan C; Birnie, David; Stadler, Robert W; Cerkvenik, Jeffrey; Feld, Gregory K; Birgersdotter-Green, Ulrika.
Afiliação
  • Hsu JC; Cardiac Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California, San Diego, San Diego, California. Electronic address: Jonathan.Hsu@ucsd.edu.
  • Birnie D; University of Ottawa Heart Institute, Ottawa, Canada.
  • Stadler RW; Medtronic plc, Mounds View, Minnesota.
  • Cerkvenik J; Medtronic plc, Mounds View, Minnesota.
  • Feld GK; Cardiac Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California, San Diego, San Diego, California.
  • Birgersdotter-Green U; Cardiac Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California, San Diego, San Diego, California.
Heart Rhythm ; 16(7): 983-989, 2019 07.
Article em En | MEDLINE | ID: mdl-31102750
BACKGROUND: The AdaptivCRT algorithm (aCRT) automatically adjusts atrioventricular delays each minute to achieve ventricular fusion through left ventricular (LV) or biventricular (BiV) pacing. aCRT is associated with superior clinical outcomes compared to standard BiV pacing, but the association of aCRT and subsequent atrial fibrillation (AF) in a real-world population has not been fully evaluated. OBJECTIVE: The purpose of this study was to investigate the incidence of AF ≥48 hours with aCRT vs standard BiV pacing after implant. METHODS: Patients implanted with a cardiac resynchronization therapy (CRT) device between 2013 and 2016 were studied via the de-identified Medtronic CareLink database. For univariate and multivariate survival analyses, Kaplan-Meier and Cox proportional hazards were used, respectively. RESULTS: Of 37,450 patients (mean age 69.1 ± 11.0 years; 67.9% male) followed for a mean 15.5 ± 9.1 months, 9.7% (n = 3647) developed ≥48 hours of AF. In univariate analysis, compared with standard BiV pacing, the aCRT BiV and LV mode was associated with a 54% lower risk of ≥48 hours of AF (P <.001) at 2 years, which persisted after multivariate adjustment (hazard ratio 0.53; 95% confidence interval 0.49-0.57; P <.001), even when stratified by sensed PR interval ≤200 ms and >200 ms. Higher percentages of LV-only pacing with aCRT were associated with lower incidence of AF (comparing >92% LV-only pacing vs 0%-5% LV-only pacing: HR 0.05; 95% CI 0.04-0.06; P <.001). CONCLUSION: In a large, real-world population of CRT recipients, aCRT pacing compared to standard BiV pacing was associated with a lower incidence of AF in patients with both long and short PR intervals. A higher percentage of LV-only pacing during aCRT was also associated with lower incidence of AF.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Estimulação Cardíaca Artificial / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Tipo de estudo: Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Heart Rhythm Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Estimulação Cardíaca Artificial / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Tipo de estudo: Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Heart Rhythm Ano de publicação: 2019 Tipo de documento: Article