DNA nanotetrahedron linked dual-aptamer based voltammetric aptasensor for cardiac troponin I using a magnetic metal-organic framework as a label.
Luo, Zibin; Sun, Duanping; Tong, Yanli; Zhong, Yongsheng; Chen, Zuanguang.
Afiliação
  • Luo Z; School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, 510006, China.
  • Sun D; School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, 510006, China. sundp@gdpu.edu.cn.
  • Tong Y; Center for Drug Research and Development, Guangdong Pharmaceutical University, Guangzhou, 510006, China. sundp@gdpu.edu.cn.
  • Zhong Y; Department of Pharmacy, Guangdong Second Provincial General Hospital, Guangzhou, 510317, China.
  • Chen Z; East Campus Lab Center, Sun Yat-Sen University, Guangzhou, 510006, China.
Mikrochim Acta ; 186(6): 374, 2019 05 23.
Article em En | MEDLINE | ID: mdl-31123904
ABSTRACT
An ultrasensitive voltammetric aptasensor was constructed to analyze cardiac troponin I (cTnI). It is based on DNA nanotetrahedron (NTH) linked dual-aptamer (dAPT) and magnetic metal organic frameworks (mMOFs) of type Fe3O4@UiO-66. Firstly, the DNA NTH linked dAPT (Tro4 and Tro6) were immobilized on a gold electrode for improving the capture efficiency of cTnI. The novel mMOFs Fe3O4@UiO-66 was then decorated by Au@Pt nanoparticles (Au@PtNPs), horseradish peroxidase (HRP), G-quadruplex/hemin (GQH) DNAzyme, and two types of aptamers to form signaling nanoprobes. In the presence of cTnI, an aptamer-protein-nanoprobe sandwich-type structure is formed. Afterward, the nanoprobes including enzyme, GQH DNAzyme and Fe3O4@UiO-66/Au@PtNP were utilized to catalyze the oxidation of hydroquinone by hydrogen peroxide for the electrochemical signals amplification, typically at a working potential of -0.1 V (vs. Ag/AgCl). The voltammetric signal increases linearly in the 0.01 to 100 ng·mL-1 cTnI concentration range, and the detection limit is 5.7 pg·mL-1. Graphical abstract An ultrasensitive voltammetric aptasensor was constructed to analyze cardiac troponin I (cTnI) based on DNA nanotetrahedron linked dual-aptamer and magnetic metal organic frameworks of type Fe3O4@UiO-66. The results indicated the aptasensor has a wide linear response range (0.01 to 100 ng/mL) and low detection limit (5.74 pg/mL) for cTnI. GE gold electrode; MCH 6-Mmercapto-1-hexanol; HRP horseradish peroxidase; HQ hydroquinone; BQ benzoquinone.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Troponina I / DNA Catalítico / Aptâmeros de Nucleotídeos / Técnicas Eletroquímicas / Estruturas Metalorgânicas Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Troponina I / DNA Catalítico / Aptâmeros de Nucleotídeos / Técnicas Eletroquímicas / Estruturas Metalorgânicas Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China