Your browser doesn't support javascript.
loading
Exploiting Self-Absorption for Plasma Characterization in Laser-Induced Breakdown Spectroscopy Experiments: A Comparison of Two Recent Approaches.
Safi, Ali; Tavassoli, S Hassan; Cristoforetti, Gabriele; Tognoni, Elisabetta; Campanella, Beatrice; Legnaioli, Stefano; Pagnotta, Stefano; Poggialini, Francesco; Palleschi, Vincenzo.
Afiliação
  • Safi A; Laser and Plasma Research Institute , Shahid Beheshti University , G. C. Evin, Tehran , Iran.
  • Tavassoli SH; Laser and Plasma Research Institute , Shahid Beheshti University , G. C. Evin, Tehran , Iran.
  • Cristoforetti G; National Institute of Optics of the National Research Council (INO-CNR) , Via G. Moruzzi 1 , Pisa , Italy.
  • Tognoni E; National Institute of Optics of the National Research Council (INO-CNR) , Via G. Moruzzi 1 , Pisa , Italy.
  • Campanella B; Applied and Laser Spectroscopy Laboratory , Institute of Chemistry of Organometallic Compounds , Via G. Moruzzi 1 , Pisa , Italy.
  • Legnaioli S; Applied and Laser Spectroscopy Laboratory , Institute of Chemistry of Organometallic Compounds , Via G. Moruzzi 1 , Pisa , Italy.
  • Pagnotta S; Applied and Laser Spectroscopy Laboratory , Institute of Chemistry of Organometallic Compounds , Via G. Moruzzi 1 , Pisa , Italy.
  • Poggialini F; Applied and Laser Spectroscopy Laboratory , Institute of Chemistry of Organometallic Compounds , Via G. Moruzzi 1 , Pisa , Italy.
  • Palleschi V; Applied and Laser Spectroscopy Laboratory , Institute of Chemistry of Organometallic Compounds , Via G. Moruzzi 1 , Pisa , Italy.
Anal Chem ; 91(13): 8595-8601, 2019 Jul 02.
Article em En | MEDLINE | ID: mdl-31149812
ABSTRACT
In this article, we compare two analytical methods that have been recently proposed the columnar density Saha-Boltzmann plot method of Cristoforetti and Tognoni (Cristoforetti, G.; Tognoni, E. Spectrochim. Acta, Part B, 2013, 79-80, 63-71) and the C-sigma model of Aragon and Aguilera (Aragon, C.; Aguilera, J. A. J. Quant. Spectrosc. Radiat. Trans. 2014, 149, 90-102). Both methods are based on the exploitation of self-absorbed lines for the characterization of plasmas in laser-induced breakdown spectroscopy experiments. However, although the two methods can be safely applied in many cases, their usefulness is limited in many practical cases of interest because of the intrinsic constraints of the used plasma model or because of the complexity of the numerical treatment. The two methods are presented here and critically discussed. Finally, an extended C-sigma approach is proposed to merge the advantages of the two methods, overcoming their intrinsic limitations and simplifying the numerical treatment.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Irã