Your browser doesn't support javascript.
loading
Immediate versus early loading protocols of titanium-zirconium narrow-diameter implants for mandibular overdentures in edentulous patients: 1-year results from a randomized controlled trial.
Reis, Rita; Nicolau, Pedro; Calha, Nuno; Messias, Ana; Guerra, Fernando.
Afiliação
  • Reis R; Dentistry Department, Faculty of Medicine, University of Coimbra, Coimbra, Portugal.
  • Nicolau P; Dentistry Department, Faculty of Medicine, University of Coimbra, Coimbra, Portugal.
  • Calha N; Dentistry Department, Faculty of Medicine, University of Coimbra, Coimbra, Portugal.
  • Messias A; Dentistry Department, Faculty of Medicine, University of Coimbra, Coimbra, Portugal.
  • Guerra F; Dentistry Department, Faculty of Medicine, University of Coimbra, Coimbra, Portugal.
Clin Oral Implants Res ; 30(10): 953-961, 2019 Oct.
Article em En | MEDLINE | ID: mdl-31278767
ABSTRACT

OBJECTIVES:

The purpose of this randomized clinical trial was to compare immediate and early loading protocols for mandibular overdentures with two-splinted narrow-diameter implants in thin, non-augmented residual ridge situations. MATERIAL AND

METHODS:

Each edentulous patient received two implants in the interforaminal region. If primary stability after implant placement was achieved, patients were randomized either to the immediate (48 hr post-surgery) or the early (2 weeks after surgery) loading group. In prosthetic rehabilitation, a bar prosthetic system with a titanium bar was used. Implant survival, success rates, and radiographic changes at the crestal bone level were evaluated after 1 year, and patient satisfaction was recorded at 1 and 6 months post-surgery.

RESULTS:

Twenty-four patients with a mean age of 67 ± 9 years were included. One patient passed away after 11 months due to treatment-independent reasons. In the 24 implants of the immediate loading group, the mean bone level change from surgery/loading to the first-year evaluation was 0.32 ± 0.80 mm (p = .066). Regarding the early group (22 implants), the mean bone level change from loading to 1 year was 0.34 ± 0.69 mm (p = .048). After 1 year, no differences could be detected between groups (p = .91) with a mean difference of 0.02 mm (95% CI [-0.42, 0.47]). The mean implant survival and success rates were 100% for both groups. Patient satisfaction was high; however, at 6 months, there was a difference between groups regarding the ability to chew.

CONCLUSIONS:

Both loading protocols for mandibular overdentures supported by two-splinted narrow-diameter implants were successful at the 1-year follow-up.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implantes Dentários / Revestimento de Dentadura Tipo de estudo: Clinical_trials / Guideline / Observational_studies / Prognostic_studies Limite: Aged / Humans / Middle aged Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Portugal

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implantes Dentários / Revestimento de Dentadura Tipo de estudo: Clinical_trials / Guideline / Observational_studies / Prognostic_studies Limite: Aged / Humans / Middle aged Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Portugal