Evaluation of performance of the GENECUBE assay for rapid molecular identification of Staphylococcus aureus and methicillin resistance in positive blood culture medium.
Hida, Yukio; Uemura, Keiichi; Sugimoto, Hiroyasu; Kawashima, Yosuke; Koyanagi, Norito; Notake, Shigeyuki; Akashi, Yusaku; Sakaguchi, Shohei; Kimura, Hideki; Suzuki, Hiromichi.
Afiliação
  • Hida Y; Department of Clinical Laboratory, University of Fukui Hospital, Yoshida-gun, Fukui, Japan.
  • Uemura K; Department of Clinical Laboratory, Chutoen General Medical Center, Kakegawa, Shizuoka, Japan.
  • Sugimoto H; Tsuruga Institute of Biotechnology, TOYOBO Co., Ltd., Tsuruga, Fukui, Japan.
  • Kawashima Y; Diagnostic System Department, TOYOBO Co., Ltd., Osaka, Osaka, Japan.
  • Koyanagi N; Department of Clinical Laboratory, Chutoen General Medical Center, Kakegawa, Shizuoka, Japan.
  • Notake S; Department of Clinical Laboratory, Tsukuba Medical Center Hospital, Tsukuba, Ibaraki, Japan.
  • Akashi Y; Department of Clinical Laboratory Medicine, Tsukuba Medical Center Hospital, Tsukuba, Ibaraki, Japan.
  • Sakaguchi S; Division of Infectious Disease, Department of Medicine, Tsukuba Medical Center Hospital, Tsukuba, Ibaraki, Japan.
  • Kimura H; Department of Clinical Laboratory, University of Fukui Hospital, Yoshida-gun, Fukui, Japan.
  • Suzuki H; Department of Clinical Laboratory, University of Fukui Hospital, Yoshida-gun, Fukui, Japan.
PLoS One ; 14(7): e0219819, 2019.
Article em En | MEDLINE | ID: mdl-31310615
ABSTRACT
Rapid identification of causative agents from positive blood culture media is a prerequisite for the timely targeted treatment of patients with sepsis. The GENECUBE (TOYOBO Co., Ltd.) is a novel, fully-automated gene analyzer that can purify DNAs and amplify target DNAs. In this study, we evaluated the ability of two newly developed GENECUBE assays to directly detect the nuc and mecA genes in blood culture medium; nuc is specific to Staphylococcus aureus, and mecA indicates methicillin resistance. We examined 263 positive blood culture samples taken at three hospitals from patients suspected of having staphylococcal bacteremia. The results were then compared with those obtained using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, antimicrobial susceptibility testing (Microscan system or Dry-plate EIKEN), and sequencing analysis. The GENECUBE assays had sensitivity and specificity of 100% in detecting both S. aureus and methicillin resistance in positive blood culture. The turnaround time of the examination was evaluated for 36 positive blood culture samples. The time between the initiation of incubation and completion of the GENECUBE examination was 23 h (interquartile range IQR 21-37 h); the time between reporting of Gram stain examination and completion of the GENECUBE examination was 52 min (IQR 48-62 min). These findings show that the GENECUBE assays significantly reduce the assay time with no loss of sensitivity or specificity.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Infecções Estafilocócicas / Staphylococcus aureus / Técnicas Bacteriológicas / Técnicas de Diagnóstico Molecular / Staphylococcus aureus Resistente à Meticilina Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Infecções Estafilocócicas / Staphylococcus aureus / Técnicas Bacteriológicas / Técnicas de Diagnóstico Molecular / Staphylococcus aureus Resistente à Meticilina Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão