Evaluation of 4D flow MRI-based non-invasive pressure assessment in aortic coarctations.
Saitta, Simone; Pirola, Selene; Piatti, Filippo; Votta, Emiliano; Lucherini, Federico; Pluchinotta, Francesca; Carminati, Mario; Lombardi, Massimo; Geppert, Christian; Cuomo, Federica; Figueroa, Carlos Alberto; Xu, Xiao Yun; Redaelli, Alberto.
Afiliação
  • Saitta S; Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy; Department of Chemical Engineering, Imperial College London, London, UK.
  • Pirola S; Department of Chemical Engineering, Imperial College London, London, UK.
  • Piatti F; 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Votta E; Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy.
  • Lucherini F; Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy.
  • Pluchinotta F; Department of Paediatric Cardiology and Adult Congenital Heart Disease, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Carminati M; Department of Paediatric Cardiology and Adult Congenital Heart Disease, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Lombardi M; Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy.
  • Geppert C; Siemens Healthcare GmbH, Erlangen, Germany.
  • Cuomo F; Departments of Surgery and Biomedical Engineering, University of Michigan, MI, USA.
  • Figueroa CA; Departments of Surgery and Biomedical Engineering, University of Michigan, MI, USA.
  • Xu XY; Department of Chemical Engineering, Imperial College London, London, UK.
  • Redaelli A; Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy. Electronic address: alberto.redaelli@polimi.it.
J Biomech ; 94: 13-21, 2019 Sep 20.
Article em En | MEDLINE | ID: mdl-31326119
ABSTRACT
Severity of aortic coarctation (CoA) is currently assessed by estimating trans-coarctation pressure drops through cardiac catheterization or echocardiography. In principle, more detailed information could be obtained non-invasively based on space- and time-resolved magnetic resonance imaging (4D flow) data. Yet the limitations of this imaging technique require testing the accuracy of 4D flow-derived hemodynamic quantities against other methodologies. With the objective of assessing the feasibility and accuracy of this non-invasive method to support the clinical diagnosis of CoA, we developed an algorithm (4DF-FEPPE) to obtain relative pressure distributions from 4D flow data by solving the Poisson pressure equation. 4DF-FEPPE was tested against results from a patient-specific fluid-structure interaction (FSI) simulation, whose patient-specific boundary conditions were prescribed based on 4D flow data. Since numerical simulations provide noise-free pressure fields on fine spatial and temporal scales, our analysis allowed to assess the uncertainties related to 4D flow noise and limited resolution. 4DF-FEPPE and FSI results were compared on a series of cross-sections along the aorta. Bland-Altman analysis revealed very good agreement between the two methodologies in terms of instantaneous data at peak systole, end-diastole and time-averaged values biases (means of differences) were +0.4 mmHg, -1.1 mmHg and +0.6 mmHg, respectively. Limits of agreement (2 SD) were ±0.978 mmHg, ±1.06 mmHg and ±1.97 mmHg, respectively. Peak-to-peak and maximum trans-coarctation pressure drops obtained with 4DF-FEPPE differed from FSI results by 0.75 mmHg and -1.34 mmHg respectively. The present study considers important validation aspects of non-invasive pressure difference estimation based on 4D flow MRI, showing the potential of this technology to be more broadly applied to the clinical practice.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coartação Aórtica / Imageamento por Ressonância Magnética / Modelos Cardiovasculares Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Biomech Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coartação Aórtica / Imageamento por Ressonância Magnética / Modelos Cardiovasculares Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Biomech Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido