Your browser doesn't support javascript.
loading
Percutaneous transcatheter closure of an aorto-cardiac fistula in a six-year-old Warmblood mare with atrial fibrillation.
Vernemmen, I; De Clercq, D; Decloedt, A; Schauvliege, S; Taeymans, Y; De Wolf, D; van Loon, G.
Afiliação
  • Vernemmen I; Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium. Electronic address: ingrid.vernemmen@ugent.be.
  • De Clercq D; Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
  • Decloedt A; Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
  • Schauvliege S; Department of Surgery and Anaesthesiology of Domestic Animals, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
  • Taeymans Y; Department of Pediatric Cardiology, University Hospital Ghent, De Pintelaan 185, 9000 Ghent, Belgium.
  • De Wolf D; Department of Pediatric Cardiology, University Hospital Ghent, De Pintelaan 185, 9000 Ghent, Belgium.
  • van Loon G; Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
J Vet Cardiol ; 24: 78-84, 2019 Aug.
Article em En | MEDLINE | ID: mdl-31405558
This report describes a rare case of an aorto-cardiac fistula in a six-year-old French Warmblood mare presented with atrial fibrillation, decreased performance, ventral oedema, bounding arterial pulsation and pathological jugular venous pulse. A 2.7-cm-diameter fistula connected the right aortic sinus of Valsalva to the right atrium. Atrial fibrillation was likely due to volume overload of the right heart due to left-to-right shunting. The horse was treated by percutaneous transcatheter closure of the fistula delivered under general anaesthesia using a transarterial approach. The operation was initially successful, and clinical signs of congestive heart failure improved immediately. However, the device dislodged six days after procedure, and the general condition of the horse deteriorated quickly. A second closure attempt to deliver the occluder using a transvenous approach in the standing horse failed, and the horse was eventually euthanized. Procedural aspects and several possible risk factors for device dislodgement are discussed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Seio Aórtico / Fístula Vascular / Átrios do Coração / Doenças dos Cavalos Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: J Vet Cardiol Assunto da revista: CARDIOLOGIA / MEDICINA VETERINARIA Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Seio Aórtico / Fístula Vascular / Átrios do Coração / Doenças dos Cavalos Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: J Vet Cardiol Assunto da revista: CARDIOLOGIA / MEDICINA VETERINARIA Ano de publicação: 2019 Tipo de documento: Article