BACKGROUND: The use of poly-l-lactide acid-based bioresorbable scaffolds is limited in daily clinical practice because of safety concerns and lack of physiological benefit. Magnesium-based bioresorbable scaffold (MgBRS) presents a short resorption period (<1 year) and have the potential of being thromboresistant and exhibiting early restoration of vasomotor function. To date, however, no randomized clinical trial has investigated the performance of MgBRS. Therefore, this study aimed to compare the in-stent/scaffold vasomotion between MgBRS and permanent metallic sirolimus-eluting stent (SES) at 12-month follow-up in ST-segment-elevation myocardial infarction patients. METHODS: This investigator-driven, multicenter, randomized, single-blind, controlled trial randomized ST-segment-elevation myocardial infarction patients 1:1 to SES or MgBRS at 11 academic centers. The primary end point was the rate of increase (≥3%) after nitroglycerin in mean lumen diameter of the in-stent/scaffold segment at 12 months with superiority of MgBRS over SES in the as-treated population. The main secondary end points included angiographic parameters of restenosis, device-oriented composite end point, their individual components, and device thrombosis rate. Besides, endothelial-dependent vasomotor response to acetylcholine (ie, endothelial function) was also assessed in a subgroup of patients (n=69). RESULTS: Between June 2017 and June 2018, 150 ST-segment-elevation myocardial infarction patients were randomized (MgBRS, n=74; SES, n=76). At 1 year, the primary end point was significantly higher in the MgBRS arm (56.5% versus 33.8%; P=0.010). Conversely, late lumen loss was significantly lower in the SES group (in-segment: 0.39±0.49mm versus 0.02±0.27mm, P<0.001; in-device: 0.61±0.55mm versus 0.06±0.21mm; P<0.001). The device-oriented composite end point was higher in the MgBRS arm driven by an increase in ischemia-driven target lesion revascularization rate (12[16.2%] versus 4[5.2%], P=0.030). Definite thrombosis rate was similar between groups (1[1.4%] in the MgBRS arm versus 2[2.6%] in the SES group; P=1.0). Endothelial function assessment at device segment evidenced a more pronounced vasoconstrictive response to maximal dose of acetylcholine in the MgBRS arm (-8.3±3.5% versus -2.4±1.3% in the SES group, P=0.003). CONCLUSIONS: When compared to SES, MgBRS demonstrated a higher capacity of vasomotor response to pharmacological agents (either endothelium-independent or endothelium-dependent) at 1 year. However, MgBRS was associated with a lower angiographic efficacy, a higher rate of target lesion revascularization, without thrombotic safety concerns. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03234348.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Angioplastia Coronária com Balão
/
Sirolimo
/
Alicerces Teciduais
/
Infarto do Miocárdio com Supradesnível do Segmento ST
Tipo de estudo:
Clinical_trials
/
Etiology_studies
/
Incidence_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Circulation
Ano de publicação:
2019
Tipo de documento:
Article