Your browser doesn't support javascript.
loading
A rapid colloidal gold-based immunochromatographic strip assay for monitoring nitroxynil in milk.
Na, Guanqiong; Hu, Xiaofei; Yang, Jifei; Sun, Yaning; Kwee, Sharon; Tang, Liang; Xing, Guangxu; Xing, Yunrui; Zhang, Gaiping.
Afiliação
  • Na G; School of Food Science and Technology, Jiangnan University, Wuxi, China.
  • Hu X; Key Laboratory for Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, Zhengzhou, China.
  • Yang J; Key Laboratory for Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, Zhengzhou, China.
  • Sun Y; Key Laboratory for Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, Zhengzhou, China.
  • Kwee S; Key Laboratory for Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, Zhengzhou, China.
  • Tang L; Department of Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX, USA.
  • Xing G; Department of Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX, USA.
  • Xing Y; Key Laboratory for Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, Zhengzhou, China.
  • Zhang G; Key Laboratory for Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, Zhengzhou, China.
J Sci Food Agric ; 100(5): 1860-1866, 2020 Mar 30.
Article em En | MEDLINE | ID: mdl-31602650
ABSTRACT

BACKGROUND:

Nitroxynil (NIT) is a veterinary drug against hepatic fluke disease for food-producing cattle and sheep. NIT has a long half-life time in animals since it is highly bound to plasma protein. Therefore NIT possibly remains in animal edible tissues or milk due to drug abuse. In this study, a specific murine monoclonal antibody (mAb) against NIT was prepared and an immunochromatographic strip assay based on the mAb was developed for screening NIT in milk.

RESULTS:

The affinity constant of the anti-NIT mAb was 2.93 × 1010 and the anti-NIT mAb had almost no cross-reactivity with other analogs, so that it showed good specificity. The cutoff value of this test strip was considered to be 50 ng mL-1 by the naked eye. When detected by the strip reader, the half maximum inhibition concentration (IC50 ) of the immunoassay strip was calculated to be 5.716 ng mL-1 and the limit of detection (LOD) was 1.146 ng mL-1 . Intra-assay recoveries from 88.80 to 97.13% were obtained, with the highest coefficient of variation (CV) at 9.01%; inter-assay recoveries ranged from 84.60 to 106.87%, with the highest CV at 9.93%.

CONCLUSION:

The operative procedure of the proposed method can be completed within 10 min. The strip developed in this study was a practical tool for rapid semiquantitative and quantitative detection of NIT in milk. This study suggested great potential for analytically monitoring NIT in other food samples. © 2019 Society of Chemical Industry.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imunoensaio / Resíduos de Drogas / Leite / Nitroxinila / Antiplatelmínticos Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: J Sci Food Agric Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imunoensaio / Resíduos de Drogas / Leite / Nitroxinila / Antiplatelmínticos Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: J Sci Food Agric Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China