Calibration of arterial spin labeling data-potential pitfalls in post-processing.
Pinto, Joana; Chappell, Michael A; Okell, Thomas W; Mezue, Melvin; Segerdahl, Andrew R; Tracey, Irene; Vilela, Pedro; Figueiredo, Patrícia.
Afiliação
  • Pinto J; Institute for Systems and Robotics and Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal.
  • Chappell MA; Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
  • Okell TW; Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom.
  • Mezue M; Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
  • Segerdahl AR; Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
  • Tracey I; Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
  • Vilela P; Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
  • Figueiredo P; Nuffield Division of Anaesthetics, Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, United Kingdom.
Magn Reson Med ; 83(4): 1222-1234, 2020 04.
Article em En | MEDLINE | ID: mdl-31605558
PURPOSE: To assess the impact of the different post-processing options in the calibration of arterial spin labeling (ASL) data on perfusion quantification and its reproducibility. THEORY AND METHODS: Absolute quantification of perfusion measurements is one of the promises of ASL techniques. However, it is highly dependent on a calibration procedure that involves a complex processing pipeline for which no standardized procedure has been fully established. In this work, we systematically compare the main ASL calibration methods as well as various post-processing calibration options, using 2 data sets acquired with the most common sequences, pulsed ASL and pseudo-continuous ASL. RESULTS: Significant and sometimes large discrepancies in ASL perfusion quantification were obtained when using different post-processing calibration options. Nevertheless, when using a set of theoretically based and carefully chosen options, only small differences were observed for both reference tissue and voxelwise methods. The voxelwise and white matter reference tissue methods were less sensitive to post-processing options than the cerebrospinal fluid reference tissue method. However, white matter reference tissue calibration also produced poorer reproducibility results. Moreover, it may also not be an appropriate reference in case of white matter pathology. CONCLUSION: Poor post-processing calibration options can lead to large errors in perfusion quantification, and a complete description of the calibration procedure should therefore be reported in ASL studies. Overall, our results further support the voxelwise calibration method proposed by the ASL white paper, particularly given the advantage of being relatively simple to implement and intrinsically correcting for the coil sensitivity profile.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Circulação Cerebrovascular Tipo de estudo: Prognostic_studies Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Portugal

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Circulação Cerebrovascular Tipo de estudo: Prognostic_studies Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Portugal