Your browser doesn't support javascript.
loading
AC Electrodeposition of PEDOT Films in Protic Ionic Liquids for Long-Term Stable Organic Electrochemical Transistors.
Ji, Jianlong; Zhu, Xiaoxian; Han, Dan; Li, Mangmang; Zhang, Qiang; Shu, Yang; Cheng, Zhengdong; Zhang, Wendong; Hua, Er; Sang, Shengbo.
Afiliação
  • Ji J; College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, China.
  • Zhu X; College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, China.
  • Han D; College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, China.
  • Li M; College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, China.
  • Zhang Q; College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, China.
  • Shu Y; Department of Chemistry, Colleges of Sciences, Northeastern University, Shenyang 110819, China.
  • Cheng Z; Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, TX 77843-3122, USA.
  • Zhang W; College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, China.
  • Hua E; Chemical Science and Engineering College, North Minzu University, Ningxia 750021, China.
  • Sang S; College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, China.
Molecules ; 24(22)2019 Nov 14.
Article em En | MEDLINE | ID: mdl-31739407
Poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS)-based organic electrochemical transistors (OECTs) are widely utilized to construct highly sensitive biosensors. However, the PSS phase exhibits insulation, weak acidity, and aqueous instability. In this work, we fabricated PEDOT OECT by alternating current electrodeposition in protic ionic liquids. The steady-state characteristics were demonstrated to be stable in long-term tests. In detail, the maximum transconductance, the on/off current ratio, and the hysteresis were stable at 2.79 mS, 504, and 0.12 V, respectively. Though the transient behavior was also stable, the time constant could reach 218.6 ms. Thus, the trade-off between switching speed and stability needs to be considered in applications that require a rapid response.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Eletroquímica / Líquidos Iônicos Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Eletroquímica / Líquidos Iônicos Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China