Hb Phnom Penh Showing Falsely High or Reasonable HbA1c Values Depending on the Type of High-performance Liquid Chromatography System.
Intern Med
; 59(6): 805-809, 2020 Mar 15.
Article
em En
| MEDLINE
| ID: mdl-31787693
ABSTRACT
We herein report a 50-year-old Chinese woman with Hb Phnom Penh (α117Phe-Ile-α118Thr) showing high or reasonable HbA1c values depending on the type of high-performance liquid chromatography (HPLC) system. A high HbA1c value of 7.5% (HPLC assay G9) and a reasonable HbA1c value of 5.2% (assay unknown) were observed. Therefore, the patient was refereed to our hospital; the oral glucose tolerance test showed normal glucose tolerance. The HbA1c values measured by an enzymatic assay, immunoassay, and affinity assay, as well as most HPLC assays were within the reference range, whereas those measured by the Tosoh HPLC systems were high.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Hemoglobinas Glicadas
/
Hemoglobinas Anormais
/
Cromatografia Líquida de Alta Pressão
Tipo de estudo:
Diagnostic_studies
Limite:
Female
/
Humans
/
Middle aged
Idioma:
En
Revista:
Intern Med
Assunto da revista:
MEDICINA INTERNA
Ano de publicação:
2020
Tipo de documento:
Article
País de afiliação:
Japão