Your browser doesn't support javascript.
loading
Clinical High-Resolution 3D-MR Spectroscopic Imaging of the Human Brain at 7 T.
Hingerl, Lukas; Strasser, Bernhard; Moser, Philipp; Hangel, Gilbert; Motyka, Stanislav; Heckova, Eva; Gruber, Stephan; Trattnig, Siegfried; Bogner, Wolfgang.
Afiliação
  • Hingerl L; From the High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Strasser B; Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA.
  • Moser P; From the High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Hangel G; From the High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Motyka S; From the High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Heckova E; From the High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Gruber S; From the High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
Invest Radiol ; 55(4): 239-248, 2020 04.
Article em En | MEDLINE | ID: mdl-31855587
ABSTRACT

OBJECTIVES:

Available clinical magnetic resonance spectroscopic imaging (MRSI) sequences are hampered by long scan times, low spatial resolution, strong field inhomogeneities, limited volume coverage, and low signal-to-noise ratio. High-resolution, whole-brain mapping of more metabolites than just N-acetylaspartate, choline, and creatine within clinically attractive scan times is urgently needed for clinical applications. The aim is therefore to develop a free induction decay (FID) MRSI sequence with rapid concentric ring trajectory (CRT) encoding for 7 T and demonstrate its clinical feasibility for mapping the whole cerebrum of healthy volunteers and patients. MATERIALS AND

METHODS:

Institutional review board approval and written informed consent were obtained. Time-efficient, 3-dimensional encoding of an ellipsoidal k-space by in-plane CRT and through-plane phase encoding was integrated into an FID-MRSI sequence. To reduce scan times further, repetition times were shortened, and variable temporal interleaves were applied. Measurements with different matrix sizes were performed to validate the CRT encoding in a resolution phantom. One multiple sclerosis patient, 1 glioma patient, and 6 healthy volunteers were prospectively measured. For the healthy volunteers, brain segmentation was performed to quantify median metabolic ratios, Cramér-Rao lower bounds (CRLBs), signal-to-noise ratios, linewidths, and brain coverage among all measured matrix sizes ranging from a 32 × 32 × 31 matrix with 6.9 × 6.9 × 4.2 mm nominal voxel size acquired in ~3 minutes to an 80 × 80 × 47 matrix with 2.7 × 2.7 × 2.7 mm nominal voxel size in ~15 minutes for different brain regions.

RESULTS:

Phantom structures with diameters down to 3 to 4 mm were visible. In vivo MRSI provided high spectral quality (median signal-to-noise ratios, >6.3 and linewidths, <0.082 ppm) and fitting quality. Cramér-Rao lower bounds were ranging from less than 22% for glutamine (highest CRLB in subcortical gray matter) to less than 9.5% for N-acetylaspartate for the 80 × 80 × 47 matrix (highest CRLB in the temporal lobe). This enabled reliable mapping of up to 8 metabolites (N-acetylaspartate, N-acetylaspartyl glutamate, total creatine, glutamine, glutamate, total choline, myo-inositol, glycine) and macromolecules for all resolutions. Coverage of the whole cerebrum allowed visualization of the full extent of diffuse and local multiple sclerosis-related neurochemical changes (eg, up to 100% increased myo-inositol). Three-dimensional brain tumor metabolic maps provided valuable information beyond that of single-slice MRSI, with up to 200% higher choline, up to 100% increased glutamine, and increased glycine in tumor tissue.

CONCLUSIONS:

Seven Tesla FID-MRSI with time-efficient CRT readouts offers clinically attractive acquisition protocols tailored either for speed or for the investigation of small pathologic details and low-abundant metabolites. This can complement clinical MR studies of various brain disorders. Significant metabolic anomalies were demonstrated in a multiple sclerosis and a glioma patient for myo-inositol, glutamine, total choline, glycine, and N-acetylaspartate concentrations.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encefalopatias / Mapeamento Encefálico / Espectroscopia de Ressonância Magnética / Imageamento Tridimensional Tipo de estudo: Guideline / Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Invest Radiol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Áustria

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encefalopatias / Mapeamento Encefálico / Espectroscopia de Ressonância Magnética / Imageamento Tridimensional Tipo de estudo: Guideline / Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Invest Radiol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Áustria