Dramatically Enhanced Immunochromatographic Assay Using Cascade Signal Amplification for Ultrasensitive Detection of Escherichia coli O157:H7 in Milk.
Fu, Jinmei; Zhou, Yaofeng; Huang, Xiaolin; Zhang, Wenjing; Wu, Yuhao; Fang, Hao; Zhang, Cunzheng; Xiong, Yonghua.
Afiliação
  • Fu J; State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China.
  • Zhou Y; Jiangxi Key Laboratory for Microscale Interdisciplinary Study , Nanchang University , Nanchang 330047 , P. R. China.
  • Huang X; State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China.
  • Zhang W; Jiangxi Key Laboratory for Microscale Interdisciplinary Study , Nanchang University , Nanchang 330047 , P. R. China.
  • Wu Y; State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China.
  • Fang H; Jiangxi Key Laboratory for Microscale Interdisciplinary Study , Nanchang University , Nanchang 330047 , P. R. China.
  • Zhang C; State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China.
  • Xiong Y; Jiangxi Key Laboratory for Microscale Interdisciplinary Study , Nanchang University , Nanchang 330047 , P. R. China.
J Agric Food Chem ; 68(4): 1118-1125, 2020 Jan 29.
Article em En | MEDLINE | ID: mdl-31895982
ABSTRACT
The conventional colloidal gold immunochromatographic assay (AuNP-ICA) cannot meet the requirements for the rapid and sensitive detection of Escherichia coli (E. coli) O157H7 because of its poor sensitivity. Herein, a novel two-step cascade signal amplification strategy that integrates in situ gold growth and nanozyme-mediated catalytic deposition was proposed to enhance the detection sensitivity of conventional AuNP-ICA dramatically. The enhanced strip displayed ultrahigh sensitivity in E. coli O157H7 detection and had a detection limit of 1.25 × 101 CFU/mL, which is approximately 400-fold lower than that of traditional AuNP-ICA (5 × 103 CFU/mL). The amplified strip had no background signal in the T-line zone in the absence of E. coli O157H7 even after one round of cascade signal amplification. The enhanced strip demonstrated excellent selectivity against E. coli O157H7 with a negligible cross-reaction to nine other common pathogens. Intra-assays and interassays showed that the improved strip has acceptable accuracy and precision for determining E. coli O157H7. The average recoveries in a real milk sample ranged from 87.33 to 112.15%, and the coefficients of variation were less than 10%. The enhanced strip also showed great potential in detecting a single E. coli O157H7 cell in a 75 µL solution.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imunoensaio / Escherichia coli O157 / Leite Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Animals Idioma: En Revista: J Agric Food Chem Ano de publicação: 2020 Tipo de documento: Article