Your browser doesn't support javascript.
loading
In Situ Growth of Metal-Organic Framework HKUST-1 on Graphene Oxide Nanoribbons with High Electrochemical Sensing Performance in Imatinib Determination.
Rezvani Jalal, Nahid; Madrakian, Tayyebeh; Afkhami, Abbas; Ghoorchian, Arash.
Afiliação
  • Rezvani Jalal N; Faculty of Chemistry , Bu-Ali Sina University , Hamedan 6517838695 , Iran.
  • Madrakian T; Faculty of Chemistry , Bu-Ali Sina University , Hamedan 6517838695 , Iran.
  • Afkhami A; Faculty of Chemistry , Bu-Ali Sina University , Hamedan 6517838695 , Iran.
  • Ghoorchian A; Faculty of Chemistry , Bu-Ali Sina University , Hamedan 6517838695 , Iran.
ACS Appl Mater Interfaces ; 12(4): 4859-4869, 2020 Jan 29.
Article em En | MEDLINE | ID: mdl-31908170
ABSTRACT
Metal-organic frameworks (MOFs) have been previously investigated as electrode materials for developing electrochemical sensors. They have usually been reported to suffer from poor conductivity and improvement in the conductivity of MOFs is still a great challenge. Here, we reported the fabrication of an electrochemical sensor based on the in situ growth of framework HKUST-1 on conductive graphene oxide nanoribbons (GONRs)-modified glassy carbon electrode (GCE) (HKUST-1/GONRs/GCE). The as-fabricated modified electrode was characterized using field emission scanning electron microscopy, transmission electron microscopy (TEM), high-resolution TEM, Fourier transform infrared, X-ray diffraction, electrochemical impedance spectroscopy, cyclic voltammetry, and Raman spectroscopy. The voltammetric response of HKUST-1/GONRs/GCE toward Imatinib (IMA), as an anticancer drug, is dramatically higher than HKUST-1/GCE because of the synergic effect of the GONRs and HKUST-1 framework. The calibration curve at the HKUST-1/GONRs/GCE for IMA covered two linear dynamic ranges, 0.04-1.0 and 1.0-80 µmol L-1, with a detection limit of 0.006 µmol L-1 (6 nmol L-1). Taking advantage of the conductivity of GONRs and large surface area of HKUST-1, a sensitive modified electrode was developed for the electrochemical determination of IMA. The present method provides an effective strategy to solve the poor conductivity of the MOFs. Finally, the obtained electrochemical performance made this modified electrode promising in the determination of IMA in urine and serum samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono / Técnicas Eletroquímicas / Mesilato de Imatinib / Estruturas Metalorgânicas / Grafite Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono / Técnicas Eletroquímicas / Mesilato de Imatinib / Estruturas Metalorgânicas / Grafite Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Irã