Investigating surrogate cerebrospinal fluid matrix compositions for use in quantitative LC-MS analysis of therapeutic antibodies in the cerebrospinal fluid.
Fogh, Jens Rose; Jacobsen, Anne-Marie; Nguyen, Tam T T N; Rand, Kasper D; Olsen, Line Rørbæk.
Afiliação
  • Fogh JR; Department of Pharmacy, University of Copenhagen, Universitetsparken 2, 2200, Copenhagen, Denmark.
  • Jacobsen AM; Translational DMPK, H. Lundbeck A/S, Ottiliavej 9, 2500, Valby, Denmark.
  • Nguyen TTTN; Translational DMPK, H. Lundbeck A/S, Ottiliavej 9, 2500, Valby, Denmark.
  • Rand KD; Department of Pharmacy, University of Copenhagen, Universitetsparken 2, 2200, Copenhagen, Denmark.
  • Olsen LR; Department of Pharmacy, University of Copenhagen, Universitetsparken 2, 2200, Copenhagen, Denmark.
Anal Bioanal Chem ; 412(7): 1653-1661, 2020 Mar.
Article em En | MEDLINE | ID: mdl-32008082
As quantitative analysis of biotherapeutics in cerebrospinal fluid (CSF) with LC-MS becomes increasingly widespread, there is a need for method developments towards higher sensitivity. By using artificial CSF (aCSF) in the development phase, the consumption of costly and sparsely available CSF can be limited. The aCSF compositions tested here were made from various dilutions of bovine serum albumin (BSA) or rat plasma to mimic the total protein concentration found in CSF. Focusing on monoclonal antibodies, the aCSF was spiked with human immunoglobulin (hIgG) and prepared with the bottom-up analysis technique using LC-MS. Assuming that the composition of the aCSF would affect the digest, the response from aCSF matrices was compared with CSF from rat, monkey, and dog in terms of estimated sample concentration and matrix effects. The samples were spiked with hIgG in the range of 10 to 1000 ng/mL and volumes of 10 µL were transferred to sample preparation. The results indicate that BSA dilutions from 300 to 2000 µg/mL and rat plasma dilutions of 0.5-2% provide the most accurate concentration estimates when compared with rat CSF. 1000 µg/mL BSA did not produce significantly different concentration estimates for 500 ng/mL samples when compared with CSF from rat, monkey, and dog, and can therefore be used as aCSF for several different species.