Your browser doesn't support javascript.
loading
Experimental investigation of far-field human cough airflows from healthy and influenza-infected subjects.
Dudalski, Nicholas; Mohamed, Ahmed; Mubareka, Samira; Bi, Ran; Zhang, Chao; Savory, Eric.
Afiliação
  • Dudalski N; Department of Mechanical and Materials Engineering, University of Western Ontario, London, ON, Canada.
  • Mohamed A; Department of Mechanical and Materials Engineering, University of Western Ontario, London, ON, Canada.
  • Mubareka S; Department of Biological Sciences, Sunnybrook Research Institute, Toronto, ON, Canada.
  • Bi R; Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada.
  • Zhang C; Department of Mechanical and Materials Engineering, University of Western Ontario, London, ON, Canada.
  • Savory E; Department of Mechanical and Materials Engineering, University of Western Ontario, London, ON, Canada.
Indoor Air ; 30(5): 966-977, 2020 09.
Article em En | MEDLINE | ID: mdl-32304605
ABSTRACT
Seasonal influenza epidemics have been responsible for causing increased economic expenditures and many deaths worldwide. Evidence exists to support the claim that the virus can be spread through the air, but the relative significance of airborne transmission has not been well defined. Particle image velocimetry (PIV) and hot-wire anemometry (HWA) measurements were conducted at 1 m away from the mouth of human subjects to develop a model for cough flow behavior at greater distances from the mouth than were studied previously. Biological aerosol sampling was conducted to assess the risk of exposure to airborne viruses. Throughout the investigation, 77 experiments were conducted from 58 different subjects. From these subjects, 21 presented with influenza-like illness. Of these, 12 subjects had laboratory-confirmed respiratory infections. A model was developed for the cough centerline velocity magnitude time history. The experimental results were also used to validate computational fluid dynamics (CFD) models. The peak velocity observed at the cough jet center, averaged across all trials, was 1.2 m/s, and an average jet spread angle of θ = 24° was measured, similar to that of a steady free jet. No differences were observed in the velocity or turbulence characteristics between coughs from sick, convalescent, or healthy participants.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tosse / Aerossóis / Influenza Humana Tipo de estudo: Prognostic_studies Limite: Adult / Humans Idioma: En Revista: Indoor Air Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tosse / Aerossóis / Influenza Humana Tipo de estudo: Prognostic_studies Limite: Adult / Humans Idioma: En Revista: Indoor Air Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá