Diagnostic Accuracy of PET/CT and Contrast Enhanced CT in Patients With Suspected Infected Aortic Aneurysms.
Eur J Vasc Endovasc Surg
; 59(6): 972-981, 2020 06.
Article
em En
| MEDLINE
| ID: mdl-32340877
ABSTRACT
OBJECTIVE:
Infected aortic aneurysms are highly lethal, and management is very demanding, requiring an early diagnosis. The aim of this study was to evaluate the diagnostic accuracy of positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (PET/CT) and contrast enhanced CT (CE-CT) in patients with suspected infected aortic aneurysms.METHODS:
PET/CT was performed in patients with clinically suspected infected aortic aneurysms, and additional CE-CT was performed if feasible. Diagnostic accuracy was assessed by two independent readers using a four point grading score for both imaging modalities. Maximum standardised uptake values (SUVmax) were calculated for quantitative measurements of metabolic activity in PET/CT. The reference standard was a combination of clinical presentation, laboratory findings, and imaging.RESULTS:
Ten patients were included prospectively in the study, 24 retrospectively; 16 patients (47%) prior to the start of antimicrobial treatment and all 34 patients prior to any vascular intervention. Thirteen of the 34 patients had an infected aortic aneurysm (38%). Proven infected aortic aneurysms were all metabolically active on PET/CT with a median SUVmax of 6.6 (interquartile range 4.7-21.8). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of PET/CT for the diagnosis of infected aortic aneurysm was 100%, 71%, 68%, 100%, and 82%, for reader 1 and 85%, 71%, 65%, 88%, and 77%, for reader 2. Respective values for CE-CT, performed in 20 patients (59%), were 63%, 75%, 63%, 75%, and 70%, for reader 1 and 88%, 50%, 54%, 86%, and 65%, for reader 2.CONCLUSION:
The diagnostic accuracy of PET/CT in the detection of infected aortic aneurysms (n = 13) is high, and higher than CE-CT. While PET/CT demonstrates an excellent sensitivity, its specificity is hampered because of false positive findings.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Aneurisma Aórtico
/
Aneurisma Infectado
/
Meios de Contraste
/
Compostos Radiofarmacêuticos
/
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
/
Screening_studies
Limite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Eur J Vasc Endovasc Surg
Assunto da revista:
ANGIOLOGIA
Ano de publicação:
2020
Tipo de documento:
Article