Your browser doesn't support javascript.
loading
Intracranial Carotid Artery Aneurysm Treatment: First Reported Case of DERIVO®Flow-Diverter Placement by Direct Carotid Artery Puncture.
Guzzardi, Giuseppe; Del Sette, Bruno; Stanca, Carmelo; Paladini, Andrea; Galbiati, Andrea; Spinetta, Marco; Cernigliaro, Massimiliano; Leigheb, Massimiliano; Carriero, Alessandro.
Afiliação
  • Guzzardi G; SCDU Department of Interventional and Neurointerventional Radiology, "Maggiore della Carità" University Hospital, 28100 Novara, Italy.
  • Del Sette B; SCDU Department of Interventional and Neurointerventional Radiology, "Maggiore della Carità" University Hospital, 28100 Novara, Italy.
  • Stanca C; SCDU Department of Interventional and Neurointerventional Radiology, "Maggiore della Carità" University Hospital, 28100 Novara, Italy.
  • Paladini A; SCDU Department of Interventional and Neurointerventional Radiology, "Maggiore della Carità" University Hospital, 28100 Novara, Italy.
  • Galbiati A; SCDU Department of Interventional and Neurointerventional Radiology, "Maggiore della Carità" University Hospital, 28100 Novara, Italy.
  • Spinetta M; SCDU Department of Interventional and Neurointerventional Radiology, "Maggiore della Carità" University Hospital, 28100 Novara, Italy.
  • Cernigliaro M; SCDU Department of Interventional and Neurointerventional Radiology, "Maggiore della Carità" University Hospital, 28100 Novara, Italy.
  • Leigheb M; Department of Health Sciences, SCDU Orthopedics and Traumatology Institute, "Maggiore della Carità" University Hospital, 28100 Novara, Italy.
  • Carriero A; SCDU Department of Interventional and Neurointerventional Radiology, "Maggiore della Carità" University Hospital, 28100 Novara, Italy.
Brain Sci ; 10(5)2020 May 25.
Article em En | MEDLINE | ID: mdl-32466200
Brain health may be threatened by aneurysm ruptures, and early recognition of these vascular malformations allows for neuroradiological intervention. Neurointerventional procedures are usually performed with femoral artery access. In patients with severe anatomical complexity of the supra-aortic vessels, however, treatment by this approach could be hindered or impossible. Flow-diverter stent deployment is an effective and safe treatment for large, wide necked intracranial aneurysms, but it requires a complete and firm stability of the coaxial system to achieve a correct and precise deployment of the device. We present the first reported Italian case of a patient with an intracranial aneurysm which was treated with Flow-diverter stent (DERIVO®; AcandisGmbH & Co. KG; Pforzheim; Germany) by direct common carotid artery puncture due to severe tortuosity of supra-aortic trunks.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Brain Sci Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Brain Sci Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália