Your browser doesn't support javascript.
loading
Preimplantation interlead ECG heterogeneity is superior to QRS complex duration in predicting mechanical super-response in patients with non-left bundle branch block receiving cardiac resynchronization therapy.
Bortolotto, Alexandre L; Verrier, Richard L; Nearing, Bruce D; Marum, Alexandre A; Araujo Silva, Bruna; Pedreira, Giovanna C; Tessarolo Silva, Fernanda; Medeiros, Sofia A; Sroubek, Jakub; Zimetbaum, Peter J; Chang, James D.
Afiliação
  • Bortolotto AL; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil.
  • Verrier RL; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts. Electronic address: rverrier@bidmc.harvard.edu.
  • Nearing BD; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Marum AA; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil.
  • Araujo Silva B; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil.
  • Pedreira GC; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil.
  • Tessarolo Silva F; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil.
  • Medeiros SA; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil.
  • Sroubek J; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Zimetbaum PJ; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Chang JD; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
Heart Rhythm ; 17(11): 1887-1896, 2020 11.
Article em En | MEDLINE | ID: mdl-32497764
BACKGROUND: Reliable quantitative preimplantation predictors of response to cardiac resynchronization therapy (CRT) are needed. OBJECTIVE: We tested the utility of preimplantation R-wave and T-wave heterogeneity (RWH and TWH, respectively) compared to standard QRS complex duration in identifying mechanical super-responders to CRT and mortality risk. METHODS: We analyzed resting 12-lead electrocardiographic recordings from all 155 patients who received CRT devices between 2006 and 2018 at our institution and met class I and IIA American College of Cardiology/American Heart Association/Heart Rhythm Society guidelines with echocardiograms before and after implantation. Super-responders (n=35, 23%) had ≥20% increase in left ventricular ejection fraction and/or ≥20% decrease in left ventricular end-systolic diameter and were compared with non-super-responders (n=120, 77%), who did not meet these criteria. RWH and TWH were measured using second central moment analysis. RESULTS: Among patients with non-left bundle branch block (LBBB), preimplantation RWH was significantly lower in super-responders than in non-super-responders in 3 of 4 lead sets (P=.001 to P=.038) and TWH in 2 lead sets (both, P=.05), with the corresponding areas under the curve (RWH: 0.810-0.891, P<.001; TWH: 0.759-0.810, P≤.005). No differences were observed in the LBBB group. Preimplantation QRS complex duration also did not differ between super-responders and non-super-responders among patients with (P=.856) or without (P=.724) LBBB; the areas under the curve were nonsignificant (both, P=.69). RWHV1-3LILII ≥ 420 µV predicted 3-year all-cause mortality in the entire cohort (P=.037), with a hazard ratio of 7.440 (95% confidence interval 1.015-54.527; P=.048); QRS complex duration ≥ 150 ms did not predict mortality (P=.27). CONCLUSION: Preimplantation interlead electrocardiographic heterogeneity but not QRS complex duration predicts mechanical super-response to CRT in patients with non-LBBB.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Volume Sistólico / Bloqueio de Ramo / Função Ventricular Esquerda / Eletrocardiografia / Terapia de Ressincronização Cardíaca / Frequência Cardíaca Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Heart Rhythm Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Volume Sistólico / Bloqueio de Ramo / Função Ventricular Esquerda / Eletrocardiografia / Terapia de Ressincronização Cardíaca / Frequência Cardíaca Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Heart Rhythm Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil