Your browser doesn't support javascript.
loading
New bioanalytical method for the quantification of (-) - hydroxycitric acid in human plasma using UPLC-MS/MS and its application in a Garcinia cambogia pharmacokinetic study.
de Carvalho Cruz, Alessandro; Suenaga, Eunice Mayumi; Prova, Shamina Saiyara; de Oliveira Neto, Jerônimo Raimundo; Ifa, Demian Rocha; da Cunha, Luiz Carlos.
Afiliação
  • de Carvalho Cruz A; Nucleus of Toxicopharmacological Studies and Research - NEPET, Faculty of Pharmacy, Federal University of Goiás, Goiânia 74605-170, Brazil. Electronic address: alesscruz@yahoo.com.br.
  • Suenaga EM; Nucleus of Bioequivalence and Clinical Trials - NuBEC, Federal University of São Paulo, São Paulo, CEP 04041-002, Brazil.
  • Prova SS; Centre for Research in Mass Spectrometry, Department of Chemistry, York University, Chemistry Building, 4700 Keele Street, Toronto, ON M3J IP3, Canada.
  • de Oliveira Neto JR; Nucleus of Toxicopharmacological Studies and Research - NEPET, Faculty of Pharmacy, Federal University of Goiás, Goiânia 74605-170, Brazil.
  • Ifa DR; Centre for Research in Mass Spectrometry, Department of Chemistry, York University, Chemistry Building, 4700 Keele Street, Toronto, ON M3J IP3, Canada.
  • da Cunha LC; Nucleus of Toxicopharmacological Studies and Research - NEPET, Faculty of Pharmacy, Federal University of Goiás, Goiânia 74605-170, Brazil.
J Pharm Biomed Anal ; 188: 113385, 2020 Sep 05.
Article em En | MEDLINE | ID: mdl-32505893
A new, rapid, selective and sensitive UPLC-MS/MS method was developed and validated for the quantification of (-) - hydroxycitric acid (HCA) in human plasma, using DL-malic acid-2,3,3-d3 as internal standard (IS) and simple protein precipitation for the sample preparations. HCA is a highly polar compound make challenging its determination in biological fluids. A specific chromatography column Acquity UPLC HSS T3 (100 × 2.1 mm, 1.8 µm), eluted with mobile phase composed of acetonitrile/ammonium hydroxide 0,1 % (15:85, v/v) were applied for the HCA quantification. The bioanalytical method showed high-throughput achieving as fast chromatographic run as 1 min per sample. No matrix effect was observed with excellent mean chromatographic peak areas ratio of 0.98 ± 0.07 and CV% of 7.17 from normal, lipemic and hemolyzed plasma lots. Calibration curves range was linear at 0.05-10 µg/mL, presenting adequate mean correlation coefficient great than 0.99. Excellent intra-assay and inter-assay precision were achieved, ranging from 5.02-12.01 % (CV%) as well as great intra- and inter-assay accuracy from 0.29-9.20 % (RE%). UPLC-MS/MS bioanalytical method was efficiently applied to the HCA pharmacokinetic study analyzing more than 670 plasma samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Garcinia cambogia / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Garcinia cambogia / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2020 Tipo de documento: Article