Scattering kernels for fast neutron therapy treatment planning.
Moffitt, Gregory B; Wootton, Landon S; Hårdemark, Björn; Sandison, George A; Laramore, George E; Parvathaneni, Upendra; Stewart, Robert D.
Afiliação
  • Moffitt GB; University of Washington School of Medicine, Department of Radiation Oncology, 1959 NE Pacific Street Box 356043, Seattle WA 98195.
Phys Med Biol ; 65(16): 165009, 2020 08 31.
Article em En | MEDLINE | ID: mdl-32512540
ABSTRACT
The University of Washington (UW) Clinical Neutron Therapy System (CNTS) has been used to treat over 3300 patients. Treatment planning for these patients is currently performed using an MV x-ray model in Pinnacle® adapted to fit measurements of fast neutron output factors, wedge factors, depth-dose and lateral profiles. While this model has provided an adequate representation of the CNTS for 3D conformal treatment planning, later versions of Pinnacle did not allow for isocentric gantry rotation machines with a source-to-axis distance of 150 cm. This restriction limited the neutron model to version 9.0 while the photon and electron treatment planning at the UW had moved on to newer versions. Also, intensity modulated neutron therapy (IMNT) is underdevelopment at the UW, and the Pinnacle neutron model developed cannot be used for inverse treatment planning. We have used the MCNP6 Monte Carlo code system to develop Collapsed Cone (CC) and Singular Value Decomposition (SVD) neutron scattering kernels suitable for integration into the RayStation treatment planning system. Kernels were generated for monoenergetic neutrons with energies ranging from 1 keV to 51 MeV, i.e. the energy range most relevant to the CNTS. Percent depth dose (PDD) profiles computed in RayStation for the CC and SVD kernels are in excellent agreement with each other for depths beyond the beam's dose build-up region (depths greater than about 1.7 cm) for open 2.8 × 2.8 cm2, 10.3 × 10.3 cm2, and 28.8 × 32.8 cm2 fields. Lateral profiles at several depths, as well as the PDD, calculated using the CC kernels in RayStation for the full CNTS energy spectrum pass a 3%/3 mm gamma test for field sizes of 2.8 × 2.8 cm2, 10.0 × 10.3 cm2, and 28.8 × 32.8 cm2.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Planejamento da Radioterapia Assistida por Computador / Método de Monte Carlo / Imagens de Fantasmas / Nêutrons Rápidos / Modelos Teóricos Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Planejamento da Radioterapia Assistida por Computador / Método de Monte Carlo / Imagens de Fantasmas / Nêutrons Rápidos / Modelos Teóricos Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2020 Tipo de documento: Article