Your browser doesn't support javascript.
loading
Ultra-low timing jitter, Ti:Al2O3 synchronization for stimulated Raman scattering and pump-probe microscopy.
Sherlock, Ben; Saint-Jalm, Sarah; Malcolm, Graeme P A; Maker, Gareth T; Moger, Julian.
Afiliação
  • Sherlock B; University of Exeter, School of Physics and Astronomy, Exeter, United Kingdom.
  • Saint-Jalm S; University of Exeter, School of Physics and Astronomy, Exeter, United Kingdom.
  • Malcolm GPA; M Squared Lasers Ltd., Glasgow, United Kingdom.
  • Maker GT; M Squared Lasers Ltd., Glasgow, United Kingdom.
  • Moger J; University of Exeter, School of Physics and Astronomy, Exeter, United Kingdom.
J Biomed Opt ; 25(6): 1-7, 2020 06.
Article em En | MEDLINE | ID: mdl-32536041
SIGNIFICANCE: Stimulated Raman scattering (SRS) and pump-probe microscopy are implementations of multiphoton microscopy that acquire high-resolution, label-free images of live samples encoded with molecular contrast. Most commercial multiphoton microscopes cannot access these techniques since they require sample illumination by two temporally synchronized ultrafast pulse trains. We present a compact and robust way of synchronizing an additional Ti:sapphire laser with a conventional single-beam multiphoton microscope to realize an instrument that can acquire images with enhanced molecular specificity. AIM: A passive optical synchronization scheme for a pair of commercially available, unmodified modelocked Ti:sapphire lasers was developed. The suitability of this synchronization scheme for advanced biomedical microscopy was investigated. APPROACH: A pair of modelocked Ti:sapphire lasers were aligned in master-slave configuration. Five percent of the master laser output was used to seed the modelocking in the slave laser cavity. The timing jitter of the master and slave pulse trains was characterized using an optical autocorrelator. The synchronized output of both lasers was coupled into a laser scanning microscope and used to acquire spectral focusing SRS and pump-probe microscopy images from biological and nonbiological samples. RESULTS: A timing jitter between the modelocked pulse trains of 0.74 fs was recorded. Spectral focusing SRS allowed spectral discrimination of polystyrene and polymethyl methacrylate beads. Pump-probe microscopy was used to record excited state lifetime curves from hemoglobin in intact red blood cells. CONCLUSION: Our work demonstrates a simple and robust method of upgrading single-beam multiphoton microscopes with an additional ultrafast laser. The resulting dual-beam instrument can be used to acquire label-free images of sample structure and composition with high biochemical specificity.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Titânio Idioma: En Revista: J Biomed Opt Assunto da revista: ENGENHARIA BIOMEDICA / OFTALMOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Titânio Idioma: En Revista: J Biomed Opt Assunto da revista: ENGENHARIA BIOMEDICA / OFTALMOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Reino Unido