Your browser doesn't support javascript.
loading
A Multiday Evaluation of Real-Time Intramuscular EMG Usability with ANN.
Waris, Asim; Zia Ur Rehman, Muhammad; Niazi, Imran Khan; Jochumsen, Mads; Englehart, Kevin; Jensen, Winnie; Haavik, Heidi; Kamavuako, Ernest Nlandu.
Afiliação
  • Waris A; Department of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan.
  • Zia Ur Rehman M; Faculty of Engineering and Applied Sciences, Riphah International University, Islamabad 46000, Pakistan.
  • Niazi IK; Center for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg University, 9220 Aalborg, Denmark.
  • Jochumsen M; Center of Chiropractic Research, New Zealand College of Chiropractic, Auckland 1060, New Zealand.
  • Englehart K; Faculty of Health and Environmental Sciences, Health and Rehabilitation Research Institute, AUT University, Auckland 0627, New Zealand.
  • Jensen W; Center for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg University, 9220 Aalborg, Denmark.
  • Haavik H; Department of Electrical and Computer Engineering, University of New Brunswick, Fredericton, NB E3B 5A3, Canada.
  • Kamavuako EN; Center for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg University, 9220 Aalborg, Denmark.
Sensors (Basel) ; 20(12)2020 Jun 15.
Article em En | MEDLINE | ID: mdl-32549396
Recent developments in implantable technology, such as high-density recordings, wireless transmission of signals to a prosthetic hand, may pave the way for intramuscular electromyography (iEMG)-based myoelectric control in the future. This study aimed to investigate the real-time control performance of iEMG over time. A novel protocol was developed to quantify the robustness of the real-time performance parameters. Intramuscular wires were used to record EMG signals, which were kept inside the muscles for five consecutive days. Tests were performed on multiple days using Fitts' law. Throughput, completion rate, path efficiency and overshoot were evaluated as performance metrics using three train/test strategies. Each train/test scheme was categorized on the basis of data quantity and the time difference between training and testing data. An artificial neural network (ANN) classifier was trained and tested on (i) data from the same day (WDT), (ii) data collected from the previous day and tested on present-day (BDT) and (iii) trained on all previous days including the present day and tested on present-day (CDT). It was found that the completion rate (91.6 ± 3.6%) of CDT was significantly better (p < 0.01) than BDT (74.02 ± 5.8%) and WDT (88.16 ± 3.6%). For BDT, on average, the first session of each day was significantly better (p < 0.01) than the second and third sessions for completion rate (77.9 ± 14.0%) and path efficiency (88.9 ± 16.9%). Subjects demonstrated the ability to achieve targets successfully with wire electrodes. Results also suggest that time variations in the iEMG signal can be catered by concatenating the data over several days. This scheme can be helpful in attaining stable and robust performance.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reconhecimento Automatizado de Padrão / Músculo Esquelético / Eletromiografia Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Paquistão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reconhecimento Automatizado de Padrão / Músculo Esquelético / Eletromiografia Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Paquistão