Your browser doesn't support javascript.
loading
Three-dimensional fast single-point macromolecular proton fraction mapping of the human brain at 0.5 Tesla.
Anisimov, Nikolay V; Pavlova, Olga S; Pirogov, Yury A; Yarnykh, Vasily L.
Afiliação
  • Anisimov NV; Faculty of Fundamental Medicine, Lomonosov Moscow State University, 117192, Moscow, Lomonosovsky Prospekt, 31-5, Russian Federation.
  • Pavlova OS; Faculty of Fundamental Medicine, Lomonosov Moscow State University, 117192, Moscow, Lomonosovsky Prospekt, 31-5, Russian Federation.
  • Pirogov YA; Faculty of Physics, Lomonosov Moscow State University, 119991, Moscow, GSP-1, Leninskie Gory, 1-2, Russian Federation.
  • Yarnykh VL; Faculty of Physics, Lomonosov Moscow State University, 119991, Moscow, GSP-1, Leninskie Gory, 1-2, Russian Federation.
Quant Imaging Med Surg ; 10(7): 1441-1449, 2020 Jul.
Article em En | MEDLINE | ID: mdl-32676363
ABSTRACT
Fast single-point macromolecular proton fraction (MPF) mapping is a recent magnetic resonance imaging (MRI) method enabling quantitative assessment of myelin content in neural tissues. To date, the reported technical implementations of MPF mapping utilized high-field MRI equipment (1.5 T or higher), while low-field applications might pose challenges due to signal-to-noise ratio (SNR) limitations and short T1 . This study aimed to evaluate the feasibility of MPF mapping of the human brain at 0.5 T. The three-dimensional MPF mapping protocol was implemented according to the single-point synthetic-reference method, which includes three spoiled gradient-echo sequences providing proton density, T1 , and magnetization transfer contrast weightings. Whole-brain MPF maps were obtained from three healthy volunteers with spatial resolution of 1.5×1.5×2 mm3 and the total scan time of 19 minutes. MPF values were measured in a series of white and gray matter structures and compared with literature data for 3 T magnetic field. MPF maps enabled high contrast between white and gray matter with notable insensitivity to paramagnetic effects in iron-rich structures, such as globus pallidus, substantia nigra, and dentate nucleus. MPF values at 0.5 T appeared in close agreement with those at 3 T. This study demonstrates the feasibility of fast MPF mapping with low-field MRI equipment and the independence of brain MPF values of magnetic field. The presented results confirm the utility of MPF as an absolute scale for MRI-based myelin content measurements across a wide range of magnetic field strengths and extend the applicability of fast MPF mapping to inexpensive low-field MRI hardware.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Quant Imaging Med Surg Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Quant Imaging Med Surg Ano de publicação: 2020 Tipo de documento: Article