Your browser doesn't support javascript.
loading
Additional diagnostic accuracy of global longitudinal strain at peak dobutamine stress in patients with moderate pretest probability of coronary artery disease.
Elamragy, Ahmed A; Abdelwahab, Mohamed A; Elremisy, Dalia R; Hassan, Mohamed; Ammar, Waleed A; Taha, Hesham S.
Afiliação
  • Elamragy AA; Cardiology Department, Cairo University, Cairo, Egypt.
  • Abdelwahab MA; Cardiology Department, Cairo University, Cairo, Egypt.
  • Elremisy DR; Cardiology Department, Cairo University, Cairo, Egypt.
  • Hassan M; Cardiology Department, Cairo University, Cairo, Egypt.
  • Ammar WA; Cardiology Department, Cairo University, Cairo, Egypt.
  • Taha HS; Cardiology Department, Cairo University, Cairo, Egypt.
Echocardiography ; 37(8): 1222-1232, 2020 08.
Article em En | MEDLINE | ID: mdl-32735066
ABSTRACT

BACKGROUND:

Previous studies confirmed the feasibility of 2D speckle tracking echocardiography (2D STE) during dobutamine stress echocardiography (DSE) in assessing myocardial ischemia in patients with previous myocardial infarction. It is unknown whether it improves the diagnostic accuracy in young patients with intermediate pretest probability for coronary artery disease (CAD) and no prior cardiovascular events.

METHODS:

We prospectively studied 101 patients by DSE and STE, followed by coronary angiography within 1 month. Significant CAD was defined as diameter stenosis ≥ 50%. Receiver operating characteristic analysis obtained global longitudinal strain (GLS) cutoff values of significant area under the curve (AUC).

RESULTS:

Mean age 53 ± 8 years, 56% females, 49 had significant CAD (group 1) and 52 had normal/mild CAD (group 2); no significant baseline differences except more males in group 1 (P .002). DSE sensitivity and specificity for CAD were 79.6% and 92.3%, respectively, positive predictive value (PPV) 90.6%, negative predictive value (NPV) 82.7%, and diagnostic accuracy 86%. At peak stress, all strain parameters were significantly lower in group 1. However, GLS had the highest AUC 0.88, P <.001. GLS cutoff value ≤ -20.5 had 89.8% sensitivity, 84.6% specificity, 84.6% PPV, 89.8% NPV, and 87% diagnostic accuracy. Combining GLS cutoff with DSE had higher AUC than either alone (0.9, P < .001) 95.9% sensitivity, 84.6% specificity, 85.5% PPV, 95.7% NPV, and 90% diagnostic accuracy.

CONCLUSION:

2D-STE-derived GLS increases DSE precision to detect CAD in intermediate pretest probability patients It improves DSE sensitivity, NPV, and accuracy. It is reproducible and has comparable specificity.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Dobutamina Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Echocardiography Assunto da revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Egito

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Dobutamina Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Echocardiography Assunto da revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Egito