ABSTRACT
CASE We present a case of a 56-year-old man who sustained a basal cervical periprosthetic fracture around a well-fixed metal-on-metal hip resurfacing arthroplasty (MoMHRA). Although several fixation methods have been described, there seems to be no consensus about the optimal fixation method for fractures around MoMHRAs. This fracture could be regarded as a Vancouver type-B1 or -C periprosthetic fracture, so we successfully treated our patient in a standard way with a dynamic hip screw (DHS) and one cannulated hip screw.

CONCLUSION:

We describe DHS fixation as a successful treatment option for periprosthetic hip fractures around well-fixed MoMHRA.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas Periprotéticas / Fixação Interna de Fraturas / Fraturas do Quadril Limite: Humans / Male / Middle aged Idioma: En Revista: JBJS Case Connect Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas Periprotéticas / Fixação Interna de Fraturas / Fraturas do Quadril Limite: Humans / Male / Middle aged Idioma: En Revista: JBJS Case Connect Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Holanda