Your browser doesn't support javascript.
loading
Reloadable Stapler Use during Peripartum Hysterectomy for Placenta Accreta Spectrum: A Novel Surgical Technique and Case Series.
Smith, Christopher G; Cottrill, Hope M; Barton, John R.
Afiliação
  • Smith CG; Division of Gynecologic Oncology, Department of Gynecology and Obstetrics, Emory University, Atlanta, Georgia.
  • Cottrill HM; Baptist Health Lexington, Lexington, Kentucky.
  • Barton JR; Baptist Health Lexington, Lexington, Kentucky.
Am J Perinatol ; 39(3): 265-271, 2022 02.
Article em En | MEDLINE | ID: mdl-32819018
OBJECTIVE: This study aimed to describe a novel surgical technique for the management of antenatally suspected placenta accreta spectrum (PAS). STUDY DESIGN: This is a retrospective, case series of patients with suspected PAS undergoing peripartum hysterectomy with a reloadable articulating stapler at a tertiary care center. RESULTS: Eighteen patients with antenatally suspected PAS were identified and underwent peripartum hysterectomy with the aid of a reloadable stapler. Mean gestational age at delivery was 344/7 ± 11/7 weeks. Mean total operative time (skin-to-skin) was 117.3 ± 39.3 minutes, and 79.8 ± 19.8 minutes for the hysterectomy. Mean blood loss for the entire case was 1,809 ± 868 mL. Mean blood loss for the hysterectomy was 431 ± 421 mL. Mean units of intraoperative red blood cells transfused was 3 ± 1 units. Mean units of postoperative red blood cells transfused was 1 ± 0.5 units. Five cases were complicated by urological injury (two intentional cystotomies). Four patients were admitted to the intensive care unit (ICU) for a mean of ≤24 hours. Mean postoperative LOS was 4.11 ± 1.45 days. Three patients had final pathology that did not demonstrate PAS while four were consistent with accreta, six increta, and five percreta. CONCLUSION: Use of a reloadable articulating stapler device as part of the surgical management of antenatally suspected PAS results in a shorter operative time (117 ± 39 minutes vs. 140-254 minutes previously reported), lower average blood loss (1,809 ± 868 mL vs. 2,500-5,000 mL previously reported) and shorter LOS (4.11 ± 1.45 days vs. 9.8 ± 13.5 days previously reported) compared with traditional cesarean hysterectomy. The reloadable stapling device offers an advantage of more rapidly achieving hemostasis in the surgical management of PAS. KEY POINTS: · PAS is associated with severe maternal morbidity.. · Decreased operative time and blood loss have many clinical benefits.. · Reloadable stapler use for PAS decreases operative time.. · Reloadable stapler use for PAS decreases operative blood loss..
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Placenta Acreta / Grampeadores Cirúrgicos / Cesárea / Hemostasia Cirúrgica / Histerectomia Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Am J Perinatol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Geórgia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Placenta Acreta / Grampeadores Cirúrgicos / Cesárea / Hemostasia Cirúrgica / Histerectomia Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Am J Perinatol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Geórgia