Your browser doesn't support javascript.
loading
Water pressure method for duodenal endoscopic submucosal dissection (with video).
Kato, Motohiko; Takatori, Yusaku; Sasaki, Motoki; Mizutani, Mari; Tsutsumi, Koshiro; Kiguchi, Yoshiyuki; Akimoto, Teppei; Mutaguchi, Makoto; Nakayama, Atsushi; Takabayashi, Kaoru; Maehata, Tadateru; Kanai, Takanori; Yahagi, Naohisa.
Afiliação
  • Kato M; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan; Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Takatori Y; Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Sasaki M; Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Mizutani M; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Tsutsumi K; Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Kiguchi Y; Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Akimoto T; Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Mutaguchi M; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Nakayama A; Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Takabayashi K; Center for Diagnostic and Therapeutic Endoscopy, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Maehata T; Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Kanai T; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
  • Yahagi N; Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.
Gastrointest Endosc ; 93(4): 942-949, 2021 04.
Article em En | MEDLINE | ID: mdl-32853646
ABSTRACT
BACKGROUND AND

AIMS:

Duodenal endoscopic submucosal dissection (ESD) is considered technically challenging and has a high risk of adverse events. However, we recently made some progress with the ESD technique and device by introducing 2 features a water pressure (WP) method and a second-generation ESD knife (DualKnife) with a water jet function (DualKnife J). The present study aimed to assess whether these changes improved the clinical outcomes of duodenal ESD.

METHODS:

This was a retrospective observational study. Among all patients who underwent ESD for superficial duodenal epithelial tumors from June 2010 to December 2018, patients in whom a single expert performed the procedure were included in this study. Various factors, including the use of the WP method and ESD devices (DualKnife or DualKnife J) and the treatment phase (early, mid, and late), were analyzed to determine whether they were associated with intraprocedural perforation and procedure time. Treatment phase was assigned by dividing the study population equally into 3 subgroups according to the treatment phase.

RESULTS:

The procedure time was significantly shorter, and the proportion of patients with intraprocedural perforations was the lowest in the late phase. Multivariate analysis of the use of the WP method revealed that it significantly decreased the intraprocedural perforation rate (odds ratio, 0.39; 95% confidence interval, 0.16-0.96), and analysis of the use of both the WP method (ß coefficient, -0.40; P < .01) and the DualKnife J (ß coefficient, -0.10; P = .032) revealed they were independently and negatively correlated with procedure time.

CONCLUSION:

The present study reveals that the WP method significantly reduced the intraprocedural perforation rate and that both the WP method and the DualKnife J significantly shortened procedure times for duodenal ESD.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Duodenais / Ressecção Endoscópica de Mucosa Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Gastrointest Endosc Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Duodenais / Ressecção Endoscópica de Mucosa Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Gastrointest Endosc Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão