Your browser doesn't support javascript.
loading
High intensity focused ultrasound treatment for diffuse uterine leiomyomatosis: a feasibility study.
Zhang, Xiaofei; Tian, Tian; Zhu, Jialiang; Lin, Bin; Feng, Xiao; Zhang, Lian; Yang, Xinhua; Aili, Aixingzi.
Afiliação
  • Zhang X; Department of Gynecology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai, China.
  • Tian T; Department of Gynecology, Shanghai Xinhua Harvard Medical Center, Shanghai, China.
  • Zhu J; Department of MRI, Shanghai First Maternity and Infant Hospital, Tongji University Scholl of Medicine, Shanghai, China.
  • Lin B; Department of Gynecology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai, China.
  • Feng X; Department of Gynecology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai, China.
  • Zhang L; State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Ultrasoundin Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.
  • Yang X; Department of Gynecology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai, China.
  • Aili A; Department of Gynecology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai, China.
Int J Hyperthermia ; 37(1): 1060-1065, 2020.
Article em En | MEDLINE | ID: mdl-32892661
ABSTRACT

OBJECTIVE:

To investigate the safety and efficacy of high-intensity focused ultrasound (HIFU) treatment for diffuse uterine leiomyomatosis (DUL).

METHODS:

Eight patients with DUL were admitted to the Department of Gynecology of Shanghai First Maternity and Infant Hospital and underwent HIFU treatment. MRI was performed before and one day after HIFU treatment for the evaluation of lesion ablation. The uterine size was measured at 3-8 months after HIFU ablation. The menstrual volume score and serum levels of hemoglobin and CA-125 were measured pre-HIFU ablation and 12-36 months post-HIFU ablation.

RESULTS:

After an average of 5.9 months of follow-up after HIFU treatment, an average uterine volume reduction of 67.6% was observed. Menstruation returned to normal in all patients, and their serum HGB and CA-125 levels also returned to normal after an average of 19.1 months of clinical follow-up. The quality of life of all patients improved significantly.

CONCLUSION:

HIFU treatment is safe and effective in the treatment of patients with DUL.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Uterinas / Leiomiomatose / Ablação por Ultrassom Focalizado de Alta Intensidade Limite: Female / Humans / Pregnancy País/Região como assunto: Asia Idioma: En Revista: Int J Hyperthermia Assunto da revista: NEOPLASIAS / TERAPEUTICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Uterinas / Leiomiomatose / Ablação por Ultrassom Focalizado de Alta Intensidade Limite: Female / Humans / Pregnancy País/Região como assunto: Asia Idioma: En Revista: Int J Hyperthermia Assunto da revista: NEOPLASIAS / TERAPEUTICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China