Your browser doesn't support javascript.
loading
Early prediction of final infarct volume with material decomposition images of dual-energy CT after mechanical thrombectomy.
Hopf-Jensen, Silke; Anraths, Max; Lehrke, Stephanie; Szymczak, Silke; Hasler, Mario; Müller-Hülsbeck, Stefan.
Afiliação
  • Hopf-Jensen S; Department of Diagnostic and Interventional Radiology and Neuroradiology, Diakonissenhospital Flensburg, Knuthstraße 1, 24939, Flensburg, Germany. hopfsi@diako.de.
  • Anraths M; Department of Diagnostic and Interventional Radiology and Neuroradiology, Diakonissenhospital Flensburg, Knuthstraße 1, 24939, Flensburg, Germany.
  • Lehrke S; Department of Diagnostic and Interventional Radiology and Neuroradiology, Diakonissenhospital Flensburg, Knuthstraße 1, 24939, Flensburg, Germany.
  • Szymczak S; Institute of Medical Informatics and Statistics, Kiel University, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany.
  • Hasler M; Faculty of Agricultural and Nutritional Sciences, Kiel University, Kiel, Germany.
  • Müller-Hülsbeck S; Department of Diagnostic and Interventional Radiology and Neuroradiology, Diakonissenhospital Flensburg, Knuthstraße 1, 24939, Flensburg, Germany.
Neuroradiology ; 63(5): 695-704, 2021 May.
Article em En | MEDLINE | ID: mdl-33025043
ABSTRACT

PURPOSE:

Evaluation of water material density images (wMDIm) of dual-energy CT (DECT) for earlier prediction of final infarct volume (fiV) in follow-up single-energy CT (SECT) and correlation with clinical outcome.

METHODS:

Fifty patients (69 years, ± 12.1, 40-90, 50% female) with middle cerebral artery (MCA) occlusions were included. Early infarct volumes were analyzed in monoenergetic images (MonoIm) and wMDIm at 60 keV and compared with the fiV in SECT 4.9 days (± 4) after thrombectomy. Association between infarct volume and functional outcome was tested by linear regression analysis.

RESULTS:

wMDIm shows a prior visible infarct demarcation (60.7 ml, ± 74.9 ml) compared with the MonoIm (37.57 ml, ± 76.7 ml). Linear regression analysis, Bland-Altman plots and Pearson correlation coefficients show a close correlation of infarct volume in wMDIm to the fiV in SECT (r = 0.86; 95% CI 0.76-0.92), compared with MonoIm and SECT (r = 0.81; 95% CI 0.69-0.89). The agreement with SECT is substantially higher in patients with infarct volumes < 70 ml (n = 33; 66%). Coefficients were smaller with r = 0.59 (95% CI 0.31; 0.78) for MonoIm and SECT compared with r = 0.77 (95% CI 0.57; 0.88) for wMDIm and SECT. At admission, the mean NIHSS score and mRS were 17.02 (± 4.7) and 4.9 (± 0.2). mRS ≤ 2 was achieved in 56% at 90 days with a mean mRS of 2.5 (± 0.8) at discharge.

CONCLUSION:

Material decomposition allows earlier visibility of the final infarct volume. This promises an earlier evaluation of the dimension and severity of infarction and may lead to faster initiation of secondary stroke prophylaxis.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Acidente Vascular Cerebral Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male Idioma: En Revista: Neuroradiology Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Acidente Vascular Cerebral Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male Idioma: En Revista: Neuroradiology Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha