Your browser doesn't support javascript.
loading
Rapid determination and continuous monitoring of propofol in microliter whole blood sample during anesthesia by paper spray ionization-mass spectrometry.
Liu, Ying; Zhang, Xiao-Hui; Mi, Wei-Dong; Zhou, Ying-Lin; Zhang, Chang-Sheng; Zhang, Xin-Xiang.
Afiliação
  • Liu Y; Beijing National Laboratory for Molecular Sciences (BNLMS), Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China.
  • Zhang XH; State Key Laboratory of Natural and Biomimetic Drugs, Peking University, Beijing, 100191, China.
  • Mi WD; Anesthesia and Operation Center, First Medical Center of Chinese PLA General Hospital, Beijing, 100853, China.
  • Zhou YL; Beijing National Laboratory for Molecular Sciences (BNLMS), Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China. zhouyl@pku.edu.cn.
  • Zhang CS; Anesthesia and Operation Center, First Medical Center of Chinese PLA General Hospital, Beijing, 100853, China. powerzcs@126.com.
  • Zhang XX; Beijing National Laboratory for Molecular Sciences (BNLMS), Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China. zxx@pku.edu.cn.
Anal Bioanal Chem ; 413(1): 279-287, 2021 Jan.
Article em En | MEDLINE | ID: mdl-33106945
ABSTRACT
Propofol is a widely used intravenous anesthetic agent in sedation and general anesthesia. To improve the safety and maintain the depth of anesthesia, it is important to develop a rapid, sensitive, and reliable method to monitor the concentration of propofol in blood during anesthesia continuously. Here, we present a novel strategy based on paper spray ionization-mass spectrometry (PSI-MS) to detect propofol. Samples (in 10 µL) were mixed with methanol as protein precipitation solvent and 2,6-dimethylphenol as internal standard. Protein micro-precipitation was achieved with methanol by vortexing and centrifuging for 5 s each, and propofol was extracted to the supernatant. PSI-MS was performed in negative ionization mode, and MS signal lasted for 1 min. The analysis of a single sample was completed within 2 min. The area ratios of propofol to internal standard were calculated for quantification. Limit of detection of 5.5 ng mL-1 and limit of quantification of 18.2 ng mL-1 were achieved for propofol in whole blood. Calibration curve was linear in the range of 0.02-10 µg mL-1. The developed method was used successfully in monitoring the propofol concentration in 3 patients' whole blood during anesthesia, showing its further application in controlling and feeding-back target concentration infusion. Graphical abstract.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Propofol / Anestésicos Intravenosos Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Propofol / Anestésicos Intravenosos Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China