Your browser doesn't support javascript.
loading
Effect of setup error in the single-isocenter technique on stereotactic radiosurgery for multiple brain metastases.
Nakano, Hisashi; Tanabe, Satoshi; Utsunomiya, Satoru; Yamada, Takumi; Sasamoto, Ryuta; Nakano, Toshimichi; Saito, Hirotake; Takizawa, Takeshi; Sakai, Hironori; Ohta, Atsushi; Abe, Eisuke; Kaidu, Motoki; Aoyama, Hidefumi.
Afiliação
  • Nakano H; Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Chuo-ku, Niigata, Japan.
  • Tanabe S; Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Chuo-ku, Niigata, Japan.
  • Utsunomiya S; Department of Radiological Technology, Niigata University Graduate School of Health Sciences, Chuo-ku, Niigata, Japan.
  • Yamada T; Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Chuo-ku, Niigata, Japan.
  • Sasamoto R; Department of Radiological Technology, Niigata University Graduate School of Health Sciences, Chuo-ku, Niigata, Japan.
  • Nakano T; Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Chuo-ku, Niigata, Japan.
  • Saito H; Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Chuo-ku, Niigata, Japan.
  • Takizawa T; Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Chuo-ku, Niigata, Japan.
  • Sakai H; Department of Radiation Oncology, Niigata Neurosurgical Hospital, Nishi-ku, Niigata, Japan.
  • Ohta A; Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Chuo-ku, Niigata, Japan.
  • Abe E; Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Chuo-ku, Niigata, Japan.
  • Kaidu M; Department of Radiology, Nagaoka Chuo General Hospital, Nagaoka, Japan.
  • Aoyama H; Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Chuo-ku, Niigata, Japan.
J Appl Clin Med Phys ; 21(12): 155-165, 2020 Dec.
Article em En | MEDLINE | ID: mdl-33119953
ABSTRACT
In conventional stereotactic radiosurgery (SRS), treatment of multiple brain metastases using multiple isocenters is time-consuming resulting in long dose delivery times for patients. A single-isocenter technique has been developed which enables the simultaneous irradiation of multiple targets at one isocenter. This technique requires accurate positioning of the patient to ensure optimal dose coverage. We evaluated the effect of six degrees of freedom (6DoF) setup errors in patient setups on SRS dose distributions for multiple brain metastases using a single-isocenter technique. We used simulated spherical gross tumor volumes (GTVs) with diameters ranging from 1.0 to 3.0 cm. The distance from the isocenter to the target's center was varied from 0 to 15 cm. We created dose distributions so that each target was entirely covered by 100% of the prescribed dose. The target's position vectors were rotated from 0°-2.0° and translated from 0-1.0 mm with respect to the three axes in space. The reduction in dose coverage for the targets for each setup error was calculated and compared with zero setup error. The calculated margins for the GTV necessary to satisfy the tolerance values for loss of GTV coverage of 3% to 10% were defined as coverage-based margins. In addition, the maximum isocenter to target distance for different 6DoF setup errors was calculated to satisfy the tolerance values. The dose coverage reduction and coverage-based margins increased as the target diameter decreased, and the distance and 6DoF setup error increased. An increase in setup error when a single-isocenter technique is used may increase the risk of missing the tumor; this risk increases with increasing distance from the isocenter and decreasing tumor size.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Radiocirurgia Limite: Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Radiocirurgia Limite: Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão