Diagnostic accuracy of TB-LAMP assay in patients with pulmonary tuberculosis...a case-control study in northern India.
Yadav, R; Daroch, P; Gupta, P; Agarwal, P; Aggarwal, A N; Sethi, S.
Afiliação
  • Yadav R; Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Daroch P; Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Gupta P; Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Agarwal P; WHO Country Office for India, New Delhi, India.
  • Aggarwal AN; Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Sethi S; Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India. Electronic address: sunilsethi10@hotmail.com.
Pulmonology ; 28(6): 449-453, 2022.
Article em En | MEDLINE | ID: mdl-33288469
ABSTRACT

SETTING:

A tertiary care hospital in North India.

OBJECTIVE:

Tuberculosis (TB) remains a major public health problem in developing countries. The diagnosis of tuberculosis is still challenging in primary care settings in endemic countries like India. WHO has endorsed loop mediated isothermal amplification assay (LAMP) for TB as a replacement for smear microscopy for peripheral settings, however, more data is required to establish the specificity of this modality for the diagnosis of TB. In this study we aim to determine the diagnostic accuracy of the TB-LAMP assay in pulmonary tuberculosis.

DESIGN:

A total of 236 patients (117 cases suspected of TB and 119 patients with non-TB pulmonary disease) were enrolled between February to July, 2018. Microbiological workups consisting of mycobacterial smear microscopy, culture, Xpert MTB/Rif and TB-LAMP were performed.

RESULTS:

From 236 samples, 18 (7.6%) were excluded from the study. TB-LAMP and Xpert MTB/RIF were positive in 46 (21.1%) and 49 (22.5%) of the samples, respectively. The sensitivity of Xpert MTB/RIF and TB-LAMP, when culture was taken as a reference standard, was 90% (95%CI 78.2-96.7) and 82% (95%CI 68.6...91.4), respectively. The specificity, positive predictive value (PPV), and negative predictive value (NPV) of TB-LAMP assay were 96.8% (95%CI 92.8...98.9), 89.1% (95%CI 77.4...95.2), and 94.4% (95%CI 90.4...96.5), respectively.

CONCLUSION:

The TB-LAMP assay showed a good specificity and sensitivity for detection ofM. tuberculosis in adults, however, for programmatic implementation, more studies are required to be conducted at peripheral level healthcare settings.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tuberculose / Tuberculose Pulmonar / Mycobacterium tuberculosis Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Humans País/Região como assunto: Asia Idioma: En Revista: Pulmonology Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tuberculose / Tuberculose Pulmonar / Mycobacterium tuberculosis Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Humans País/Região como assunto: Asia Idioma: En Revista: Pulmonology Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Índia