Your browser doesn't support javascript.
loading
Computer vision applied to dual-energy computed tomography images for precise calcinosis cutis quantification in patients with systemic sclerosis.
Chandrasekaran, Anita C; Fu, Zhicheng; Kraniski, Reid; Wilson, F Perry; Teaw, Shannon; Cheng, Michelle; Wang, Annie; Ren, Shangping; Omar, Imran M; Hinchcliff, Monique E.
Afiliação
  • Chandrasekaran AC; Yale School of Medicine, Section of Rheumatology, Allergy & Immunology, The Anlyan Center, 300 Cedar Street, PO BOX 208031, New Haven, CT, 06520, USA.
  • Fu Z; Department of Computer Science, Illinois Institute of Technology, 10 W 31st St, Chicago, IL, 60616, USA.
  • Kraniski R; Motorola Mobility LLC, 222 W Merchandise Mart Plaza #1800, Chicago, IL, 60654, USA.
  • Wilson FP; Department of Radiology, Yale School of Medicine, 330 Cedar St, New Haven, CT, 06520, USA.
  • Teaw S; Clinical and Translational Research Accelerator, Department of Medicine, Yale School of Medicine, Temple Medical Center, 60 Temple Street Suite 6C, New Haven, CT, 06510, USA.
  • Cheng M; Yale School of Medicine, Section of Rheumatology, Allergy & Immunology, The Anlyan Center, 300 Cedar Street, PO BOX 208031, New Haven, CT, 06520, USA.
  • Wang A; Yale School of Medicine, Section of Rheumatology, Allergy & Immunology, The Anlyan Center, 300 Cedar Street, PO BOX 208031, New Haven, CT, 06520, USA.
  • Ren S; Department of Radiology, Yale School of Medicine, 330 Cedar St, New Haven, CT, 06520, USA.
  • Omar IM; Department of Computer Science, Illinois Institute of Technology, 10 W 31st St, Chicago, IL, 60616, USA.
  • Hinchcliff ME; Department of Computer Science, San Diego State University, 5500 Campanile Drive, San Diego, CA, 92182, USA.
Arthritis Res Ther ; 23(1): 6, 2021 01 06.
Article em En | MEDLINE | ID: mdl-33407814
ABSTRACT

BACKGROUND:

Although treatments have been proposed for calcinosis cutis (CC) in patients with systemic sclerosis (SSc), a standardized and validated method for CC burden quantification is necessary to enable valid clinical trials. We tested the hypothesis that computer vision applied to dual-energy computed tomography (DECT) finger images is a useful approach for precise and accurate CC quantification in SSc patients.

METHODS:

De-identified 2-dimensional (2D) DECT images from SSc patients with clinically evident lesser finger CC lesions were obtained. An expert musculoskeletal radiologist confirmed accurate manual segmentation (subtraction) of the phalanges for each image as a gold standard, and a U-Net Convolutional Neural Network (CNN) computer vision model for segmentation of healthy phalanges was developed and tested. A validation study was performed in an independent dataset whereby two independent radiologists manually measured the longest length and perpendicular short axis of each lesion and then calculated an estimated area by assuming the lesion was elliptical using the formula long axis/2 × short axis/2 × π, and a computer scientist used a region growing technique to calculate the area of CC lesions. Spearman's correlation coefficient, Lin's concordance correlation coefficient with 95% confidence intervals (CI), and a Bland-Altman plot (Stata V 15.1, College Station, TX) were used to test for equivalence between the radiologists' and the CNN algorithm-generated area estimates.

RESULTS:

Forty de-identified 2D DECT images from SSc patients with clinically evident finger CC lesions were obtained and divided into training (N = 30 with image rotation × 3 to expand the set to N = 120) and test sets (N = 10). In the training set, five hundred epochs (iterations) were required to train the CNN algorithm to segment phalanges from adjacent CC, and accurate segmentation was evaluated using the ten held-out images. To test model performance, CC lesional area estimates calculated by two independent radiologists and a computer scientist were compared (radiologist 1 vs. radiologist 2 and radiologist 1 vs. computer vision approach) using an independent test dataset comprised of 31 images (8 index finger and 23 other fingers). For the two radiologists', and the radiologist vs. computer vision measurements, Spearman's rho was 0.91 and 0.94, respectively, both p < 0.0001; Lin's concordance correlation coefficient was 0.91 (95% CI 0.85-0.98, p < 0.001) and 0.95 (95% CI 0.91-0.99, p < 0.001); and Bland-Altman plots demonstrated a mean difference between radiologist vs. radiologist, and radiologist vs. computer vision area estimates of - 0.5 mm2 (95% limits of agreement - 10.0-9.0 mm2) and 1.7 mm2 (95% limits of agreement - 6.0-9.5 mm2, respectively.

CONCLUSIONS:

We demonstrate that CNN quantification has a high degree of correlation with expert radiologist measurement of finger CC area measurements. Future work will include segmentation of 3-dimensional (3D) images for volumetric and density quantification, as well as validation in larger, independent cohorts.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escleroderma Sistêmico / Calcinose Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Arthritis Res Ther Assunto da revista: REUMATOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escleroderma Sistêmico / Calcinose Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Arthritis Res Ther Assunto da revista: REUMATOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos