Your browser doesn't support javascript.
loading
COMPARISON OF SINGLE DRUSEN SIZE ON COLOR FUNDUS PHOTOGRAPHY AND SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY.
Kim, Dong Yoon; Loo, Jessica; Farsiu, Sina; Jaffe, Glenn J.
Afiliação
  • Kim DY; Department of Ophthalmology, Chungbuk National University Hospital, College of Medicine, Chungbuk National University, Cheongju, Korea; and.
  • Loo J; Departments of Ophthalmology, and.
  • Farsiu S; Biomedical Engineering, Duke University, Durham, North Carolina.
  • Jaffe GJ; Departments of Ophthalmology, and.
Retina ; 41(8): 1715-1722, 2021 Aug 01.
Article em En | MEDLINE | ID: mdl-33411474
ABSTRACT

PURPOSE:

To determine the relationship of drusen size as determined by spectral-domain optical coherence tomography (SD-OCT) with that measured on registered color fundus photography (CFP) images and to derive an OCT-based classification system that was comparable with that determined by CFP.

METHODS:

Custom software was developed to register CFP images to the scanning laser ophthalmoscopy fundus images obtained simultaneously with the corresponding SD-OCT images, so that individual drusen observed on CFP could be matched with those seen on SD-OCT. Single druse size (diameter, area, volume, and height) on CFP and SD-OCT images from a phase two clinical trial was determined with the Duke OCT Retinal Analysis Program.

RESULTS:

The sizes of 213 individual drusen were measured on CFP and SD-OCT. The drusen diameter measured on CFP was significantly correlated with those determined on SD-OCT (R 0.879, P < 0.001). Based on the corresponding formula drusen diameter on SD-OCT = 0.77 × (drusen diameter on CFP) + 50.67 µm, large drusen defined as ≥125 µm on CFP had a diameter ≥145 µm on OCT, medium drusen defined as 63 µm to 124 µm on CFP had diameters 100 µm to 144 µm on OCT, and small drusen defined as <63 µm on CFP had diameters <100 µm on OCT.

CONCLUSION:

With our registration software and imaging processing algorithms, we were able to correlate individual druse sizes measured on CFP with those determined on SD-OCT. These data can be used to develop an SD-OCT-based grading scale, analogous to the CFP Age-Related Eye Disease Study drusen scale that may be useful in the clinic and in clinical trials.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oftalmoscopia / Retina / Algoritmos / Angiofluoresceinografia / Fotografação / Drusas Retinianas / Tomografia de Coerência Óptica Limite: Humans Idioma: En Revista: Retina Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oftalmoscopia / Retina / Algoritmos / Angiofluoresceinografia / Fotografação / Drusas Retinianas / Tomografia de Coerência Óptica Limite: Humans Idioma: En Revista: Retina Ano de publicação: 2021 Tipo de documento: Article