Your browser doesn't support javascript.
loading
Design of a Single Layer Metamaterial for Pressure Offloading of Transtibial Amputees.
Brown, Nathan; Owen, Meredith K; Garland, Anthony; DesJardins, John D; Fadel, Georges M.
Afiliação
  • Brown N; Department of Mechanical Engineering, Clemson University, 218 South Palmetto Building, Clemson, SC 29631.
  • Owen MK; Department of Bioengineering, Clemson University, 118 Engineering Service Drive, Clemson, SC 29634.
  • Garland A; Center for Integrated Nanotechnologies, Sandia National Laboratories, 1515 Eubank Building SE, Albuquerque, NM 87123.
  • DesJardins JD; Department of Bioengineering, Clemson University, 118 Engineering Service Drive, Clemson, SC 29634.
  • Fadel GM; Department of Mechanical Engineering, Clemson University, 218 South Palmetto Building, Clemson, SC 29631.
J Biomech Eng ; 143(5)2021 05 01.
Article em En | MEDLINE | ID: mdl-33493283
ABSTRACT
While using a prosthesis, transtibial amputees can experience pain and discomfort brought on by large pressure gradients at the interface between the residual limb and the prosthetic socket. Current prosthetic interface solutions attempt to alleviate these pressure gradients using soft homogenous liners to reduce and distribute pressures. This research investigates an additively manufactured metamaterial inlay with a tailored mechanical response to reduce peak pressure gradients around the limb. The inlay uses a hyperelastic behaving metamaterial (US10244818) comprised of triangular pattern unit cells, 3D printed with walls of various thicknesses controlled by draft angles. The hyperelastic material properties are modeled using a Yeoh third-order model. The third-order coefficients can be adjusted and optimized, which corresponds to a change in the unit cell wall thickness to create an inlay that can meet the unique offloading needs of an amputee. Finite element analysis simulations evaluated the pressure gradient reduction from (1) a standard homogenous silicone liner, (2) a prosthetist's inlay prescription that utilizes three variations of the metamaterial, and (3) a metamaterial solution with optimized Yeoh third-order coefficients. Compared to a traditional homogenous silicone liner for two unique limb loading scenarios, the prosthetist prescribed inlay and the optimized material inlay can achieve equal or greater pressure gradient reduction capabilities. These preliminary results show the potential feasibility of implementing this metamaterial as a method of personalized medicine for transtibial amputees by creating a customizable interface solution to meet the unique performance needs of an individual patient.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Membros Artificiais Idioma: En Revista: J Biomech Eng Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Membros Artificiais Idioma: En Revista: J Biomech Eng Ano de publicação: 2021 Tipo de documento: Article