Your browser doesn't support javascript.
loading
Two-dimensional correlation (2D) method for improving the accuracy of OCT-based noninvasive blood glucose concentration (BGC) monitoring.
Su, Ya; Liu, Huiqing; Wang, Hongjie; Chen, Lei; Yang, Guoqing; Xin, Haishu; Yao, X Steve.
Afiliação
  • Su Y; Photonics Information Innovation Center, Hebei Provincial Center for Optical Sensing Innovations, College of Physics Science & Technology, Hebei University, Wusidonglu NO. 180, Baoding, 071002, China.
  • Liu H; Photonics Information Innovation Center, Hebei Provincial Center for Optical Sensing Innovations, College of Physics Science & Technology, Hebei University, Wusidonglu NO. 180, Baoding, 071002, China.
  • Wang H; Affiliated Hospital, Hebei University, Baoding, China.
  • Chen L; Affiliated Hospital, Hebei University, Baoding, China.
  • Yang G; Photonics Information Innovation Center, Hebei Provincial Center for Optical Sensing Innovations, College of Physics Science & Technology, Hebei University, Wusidonglu NO. 180, Baoding, 071002, China.
  • Xin H; Photonics Information Innovation Center, Hebei Provincial Center for Optical Sensing Innovations, College of Physics Science & Technology, Hebei University, Wusidonglu NO. 180, Baoding, 071002, China.
  • Yao XS; Photonics Information Innovation Center, Hebei Provincial Center for Optical Sensing Innovations, College of Physics Science & Technology, Hebei University, Wusidonglu NO. 180, Baoding, 071002, China. steveyao888@yahoo.com.
Lasers Med Sci ; 36(8): 1649-1659, 2021 Oct.
Article em En | MEDLINE | ID: mdl-33523391
ABSTRACT
The optical scattering coefficient (µs) in the dermis layer of human skin obtained with optical coherence tomography (OCT) has shown to have a strong correlation with the blood glucose concentration (BGC), which can be used for noninvasive BGC monitoring. Unfortunately, the nonhomogeneity in the skin may cause inaccuracies for the BGC analysis. In this paper, we propose a 2D correlation analysis method to identify 2D regions in the skin with µs sensitive to BGC variations and only use data in these regions to calculate µs for minimizing the inaccuracy induced by nonhomogeneity and therefore improving the accuracy of OCT-based BGC monitoring. We demonstrate the effectiveness of the 2D method with OCT data obtained with in vivo human forearm skins of nine different human subjects. In particular, we present a 3D OCT data set in a two-dimensional (2D) map of depth vs. a lateral dimension and calculate the correlation coefficient R between the µs and the BGC in each region of the 2D map with the BGC data measured with a glucose meter using finger blood. We filter out the µs data from regions with low R values and only keep the µs data with R values sufficiently high (R-filter). The filtered µs data in all the regions are then averaged to produce an average µs data. We define a term called overall relevancy (OR) to quantify the degree of correlation between the filtered/averaged µs data and the finger-blood BGC data to determine the optimal R value for such an R-filter with the highest obtained OR. We found that the optimal R for such an R-filter has an absolute value (|R|) of 0.6 or 0.65. We further show that the R-filter obtained with the 2D correlation method yields better OR between µs and the BGC than that obtained with the previously reported 1D correlation method. We believe that the method demonstrated in this paper is important for understanding the influence of BGC on µs in human skins and therefore for improving the accuracy of OCT-based noninvasive BGC monitoring, although further studies are required to validate its effectiveness.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glicemia / Tomografia de Coerência Óptica Limite: Humans Idioma: En Revista: Lasers Med Sci Assunto da revista: BIOTECNOLOGIA / RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glicemia / Tomografia de Coerência Óptica Limite: Humans Idioma: En Revista: Lasers Med Sci Assunto da revista: BIOTECNOLOGIA / RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China