Contrast-Enhanced Ultrasound of the Pleural Cavity: A Method to Locate Pleural Catheters and Identify Fibrous Septa.
Bi, Ke; Wang, Bin; Zhang, Yi; Shen, Meng-Jun; Chen, Hong-Wei; Zhu, Hui-Ming; Tang, Chun-Hong; Wang, Yin.
Afiliação
  • Bi K; Department of Ultrasound, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China; Department of Pathology, Tongji Hospital, Tongji University School of Medicine, Shanghai, China.
  • Wang B; Department of Radiology, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China.
  • Zhang Y; Department of Ultrasound, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China.
  • Shen MJ; Department of Ultrasound, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China.
  • Chen HW; Department of Ultrasound, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China.
  • Zhu HM; Department of Ultrasound, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China.
  • Tang CH; Department of Ultrasound, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China.
  • Wang Y; Department of Ultrasound, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China. Electronic address: lpbbl@aliyun.com.
Ultrasound Med Biol ; 47(5): 1261-1268, 2021 05.
Article em En | MEDLINE | ID: mdl-33541751
ABSTRACT
We aimed to explore the value of contrast-enhanced ultrasound (CEUS) of the pleural cavity in locating catheters and identifying fibrous septa and to compare CEUS with multiple existing methods. We included 304 participants whose pleural effusion could not continue to be drained and compared the catheter-localization capabilities of empirical diagnosis, B-mode ultrasound with normal saline and CEUS, with computed tomography as the reference standard. CEUS performed the best (accuracy, 100%; sensitivity, 100%; specificity, 100%), followed by B-mode ultrasound with normal saline (accuracy, 77.78%; sensitivity, 62.5%; specificity, 100%), and finally empirical diagnosis (accuracy, 54.17%; sensitivity, 66.67%; specificity, 33.33%). The capabilities of CEUS and computed tomography to identify fibrous septa were evaluated, with B-mode ultrasound as the reference, and CEUS (accuracy, 100%; sensitivity, 100%; specificity, 100%) was superior to computed tomography (accuracy, 82.41%; sensitivity, 26.09%; specificity, 97.65%). Overall, CEUS can accurately locate catheters and identify fibrous septa, with performance superior to existing methods.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Meios de Contraste / Cavidade Pleural Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Meios de Contraste / Cavidade Pleural Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China