Your browser doesn't support javascript.
loading
Effectiveness of intubation devices in patients with cervical spine immobilisation: a systematic review and network meta-analysis.
Singleton, Barry N; Morris, Fiachra K; Yet, Barbaros; Buggy, Donal J; Perkins, Zane B.
Afiliação
  • Singleton BN; Department of Anaesthesiology and Critical Care Medicine, Our Lady's Children's Hospital Crumlin, Dublin, Ireland. Electronic address: barry.singleton@gmail.com.
  • Morris FK; Department of Anaesthesiology and Critical Care Medicine, Beaumont Hospital, Dublin, Ireland.
  • Yet B; Graduate School of Informatics, Middle East Technical University, Ankara, Turkey.
  • Buggy DJ; Department of Anaesthesiology and Perioperative Medicine, Mater University Hospital, School of Medicine, University College Dublin, Dublin, Ireland.
  • Perkins ZB; Centre for Trauma Sciences, Queen Mary University of London, London, UK.
Br J Anaesth ; 126(5): 1055-1066, 2021 May.
Article em En | MEDLINE | ID: mdl-33610262
BACKGROUND: Cervical spine immobilisation increases the difficulty of tracheal intubation. Many intubation devices have been evaluated in this setting, but their relative performance remains uncertain. METHODS: MEDLINE, EMBASE, and the Cochrane Library were searched to identify randomised trials comparing two or more intubation devices in adults with cervical spine immobilisation. After critical appraisal, a random-effects network meta-analysis was used to pool and compare device performance. The primary outcome was the probability of first-attempt intubation success (first-pass success). For relative performance, the Macintosh direct laryngoscopy blade was chosen as the reference device. RESULTS: We included 80 trials (8039 subjects) comparing 26 devices. Compared with the Macintosh, McGrath™ (odds ratio [OR]=11.5; 95% credible interval [CrI] 3.19-46.20), C-MAC D Blade™ (OR=7.44; 95% CrI, 1.06-52.50), Airtraq™ (OR=5.43; 95% CrI, 2.15-14.2), King Vision™ (OR=4.54; 95% CrI, 1.28-16.30), and C-MAC™ (OR=4.20; 95% CrI=1.28-15.10) had a greater probability of first-pass success. This was also true for the GlideScope™ when a tube guide was used (OR=3.54; 95% CrI, 1.05-12.50). Only the Airway Scope™ had a better probability of first-pass success compared with the Macintosh when manual-in-line stabilisation (MILS) was used as the immobilisation technique (OR=7.98; 95% CrI, 1.06-73.00). CONCLUSIONS: For intubation performed with cervical immobilisation, seven devices had a better probability of first-pass success compared with the Macintosh. However, more studies using MILS (rather than a cervical collar or other alternative) are needed, which more accurately represent clinical practice. CLINICAL TRIAL REGISTRATION: PROSPERO 2019 CRD42019158067 (https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=158067).