Your browser doesn't support javascript.
loading
Mapping Solvent Entrapment in Multiphase Systems by Electrogenerated Chemiluminescence.
Glasscott, Matthew W; Voci, Silvia; Kauffmann, Philip J; Chapoval, Andrei I; Dick, Jeffrey E.
Afiliação
  • Glasscott MW; Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States.
  • Voci S; Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States.
  • Kauffmann PJ; Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States.
  • Chapoval AI; Russian-American Anti-Cancer Center, Altai State University, Barnaul 656049, Russia.
  • Dick JE; Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States.
Langmuir ; 37(9): 2907-2912, 2021 03 09.
Article em En | MEDLINE | ID: mdl-33625240
The interfacial properties of multiphase systems are often difficult to quantify. We describe the observation and quantification of immiscible solvent entrapment on a carbonaceous electrode surface using microscopy-coupled electrogenerated chemiluminescence (ECL). As aqueous microdroplets suspended in 1,2-dichloroethane collide with a glassy carbon electrode surface, small volumes of the solvent become entrapped between the electrode and aqueous phase, resulting in an overestimation of the true microdroplet/electrode contact area. To quantify the contribution of solvent entrapment decreasing the microdroplet contact area, we drive an ECL reaction within the microdroplet phase using tris(bipyridine)ruthenium(II) chloride ([Ru(bpy)3]Cl2) as the ECL luminophore and sodium oxalate (Na2C2O4) as the co-reactant. Importantly, the hydrophilicity of sodium oxalate ensures that the reaction proceeds in the aqueous phase, permitting a clear contrast between the aqueous and 1,2-dichloroethane present at the electrode interface. With the contrast provided by ECL imaging, we quantify the microdroplet radius, apparent microdroplet contact area (aqueous + entrapped 1,2-dichloroethane), entrapped solvent contact area, and the number of entrapped solvent pockets per droplet. These data permit the extraction of the true microdroplet/electrode contact area for a given droplet, as well as a statistical assessment regarding the probability of solvent entrapment based on microdroplet size.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Langmuir Assunto da revista: QUIMICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Langmuir Assunto da revista: QUIMICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos