Your browser doesn't support javascript.
loading
Detection of Gadolinium with an Impedimetric Platform Based on Gold Electrodes Functionalized by 2-Methylpyridine-Substituted Cyclam.
Touzi, Hassen; Chevalier, Yves; Martin, Marie; Ben Ouada, Hafedh; Jaffrezic-Renault, Nicole.
Afiliação
  • Touzi H; Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, University of Monastir, Monastir 5000, Tunisia.
  • Chevalier Y; Laboratory for Process Control and Chemical Engineering (LAGEP), University of Lyon, LAGEPP UMR CNRS 5007, 43 Bd 11 Novembre 1918, 69622 Villeurbanne CEDEX, France.
  • Martin M; Institute of Analytical Sciences, University of Lyon, ISA UMR CNRS 5280, 5 Rue de La Doua, 69100 Villeurbanne, France.
  • Ben Ouada H; Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, University of Monastir, Monastir 5000, Tunisia.
  • Jaffrezic-Renault N; Institute of Analytical Sciences, University of Lyon, ISA UMR CNRS 5280, 5 Rue de La Doua, 69100 Villeurbanne, France.
Sensors (Basel) ; 21(5)2021 Feb 28.
Article em En | MEDLINE | ID: mdl-33670860
ABSTRACT
Gadolinium is extensively used in pharmaceuticals and is very toxic, so its sensitive detection is mandatory. This work presents the elaboration of a gadolinium chemical sensor based on 2-methylpyridine-substituted cyclam thin films, deposited on gold electrodes, using electrochemical impedance spectroscopy (EIS). The 2-methylpyridine-substituted cyclam (bis-N-MPyC) was synthesized in three steps, including the protection of cyclam by the formation of its CH2-bridged aminal derivative; the product was characterized by liquid 1H and 13C NMR spectroscopy. Spin-coated thin films of bis-N-MPyC on gold wafers were characterized by means of infrared spectroscopy in ATR (Attenuated Total Reflectance) mode, contact angle measurements and atomic force microscopy. The impedimetric chemical sensor was studied in the presence of increasing concentrations of lanthanides (Gd3+, Eu3+, Tb3+, Dy3+). Nyquist plots were fitted with an equivalent electrical circuit including two RC circuits in series corresponding to the bis-N-MPyC film and its interface with the electrolyte. The main parameter that varies with gadolinium concentration is the resistance of the film/electrolyte interface (Rp), correlated to the rate of exchange between the proton and the lanthanide ion. Based on this parameter, the detection limit obtained is 35 pM. The bis-N-MPyC modified gold electrode was tested for the detection of gadolinium in spiked diluted negative urine control samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Ouro Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Tunísia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Ouro Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Tunísia