Performance of a sensitive haemozoin-based malaria diagnostic test validated for vivax malaria diagnosis in Brazilian Amazon.
de Melo, Gisely Cardoso; Netto, Rebeca Linhares Abreu; Mwangi, Victor Irungu; Salazar, Yanka Evellyn Alves Rodrigues; de Souza Sampaio, Vanderson; Monteiro, Wuelton Marcelo; de Almeida E Val, Fernando Fonseca; Rocheleau, Anne; Thota, Priyaleela; Lacerda, Marcus Vinícius Guimarães.
Afiliação
  • de Melo GC; Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, 69040-000, Brazil. cardosogisely@gmail.com.
  • Netto RLA; Universidade do Estado do Amazonas (UEA), Manaus, Amazonas, 69040-000, Brazil. cardosogisely@gmail.com.
  • Mwangi VI; Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, 69040-000, Brazil.
  • Salazar YEAR; Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, 69040-000, Brazil.
  • de Souza Sampaio V; Universidade do Estado do Amazonas (UEA), Manaus, Amazonas, 69040-000, Brazil.
  • Monteiro WM; Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, 69040-000, Brazil.
  • de Almeida E Val FF; Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, 69040-000, Brazil.
  • Rocheleau A; Universidade do Estado do Amazonas (UEA), Manaus, Amazonas, 69040-000, Brazil.
  • Thota P; Fundação de Vigilância em Saúde (FVS) - Manaus, Manaus, Amazonas, 69093-018, Brazil.
  • Lacerda MVG; Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, 69040-000, Brazil.
Malar J ; 20(1): 146, 2021 Mar 12.
Article em En | MEDLINE | ID: mdl-33712019
ABSTRACT

BACKGROUND:

Vivax malaria diagnosis remains a challenge in malaria elimination, with current point of care rapid diagnostic tests (RDT) missing many clinically significant infections because of usually lower peripheral parasitaemia. Haemozoin-detecting assays have been suggested as an alternative to immunoassay platforms but to date have not reached successful field deployment. Haemozoin is a paramagnetic crystal by-product of haemoglobin digestion by malaria parasites and is present in the food vacuole of malaria parasite-infected erythrocytes. This study aimed to compare the diagnostic capability of a new haemozoin-detecting platform, the Gazelle™ device with optical microscopy, RDT and PCR in a vivax malaria-endemic region.

METHODS:

A comparative, double-blind study evaluating symptomatic malaria patients seeking medical care was conducted at an infectious diseases reference hospital in the western Brazilian Amazon. Optical microscopy, PCR, RDT, and Gazelle™ were used to analyse blood samples. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and Kappa values were calculated.

RESULTS:

Out of 300 patients, 24 test results were excluded from the final analysis due to protocol violation (6) and inconclusive and/or irretrievable results (18). Gazelle™ sensitivity was 96.1 % (91.3-98.3) and 72.1 % (65.0-78.3) when compared to optical microscopy and PCR, respectively whereas it was 83.9 % and 62.8 % for RDTs. The platform presented specificity of 100 % (97.4-100), and 99.0 % (94.8-99.9) when compared to optical microscopy, and PCR, respectively, which  was the same for RDTs. Its correct classification rate was 98.2 % when compared to optical microscopy and 82.3 % for PCR; the test's accuracy when compared to optical microscopy was 98.1 % (96.4-99.7), when compared to RDT was 95.2 % (93.0-97.5), and when compared to PCR was 85.6 % (82.1-89.1). Kappa (95 % CI) values for Gazelle™ were 96.4 (93.2-99.5), 88.2 (82.6-93.8) and 65.3 (57.0-73.6) for optical microscopy, RDT and PCR, respectively.

CONCLUSIONS:

The Gazelle™ device was shown to have faster, easier, good sensitivity, specificity, and accuracy when compared to microscopy and was superior to RDT, demonstrating to be an alternative for vivax malaria screening particularly in areas where malaria is concomitant with other febrile infections (including dengue fever, zika, chikungunya, Chagas, yellow fever, babesiosis).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Malária Vivax / Testes Diagnósticos de Rotina / Reação em Cadeia da Polimerase em Tempo Real / Testes Imediatos / Hemeproteínas / Microscopia Tipo de estudo: Clinical_trials / Diagnostic_studies / Guideline / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En Revista: Malar J Assunto da revista: MEDICINA TROPICAL Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Malária Vivax / Testes Diagnósticos de Rotina / Reação em Cadeia da Polimerase em Tempo Real / Testes Imediatos / Hemeproteínas / Microscopia Tipo de estudo: Clinical_trials / Diagnostic_studies / Guideline / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En Revista: Malar J Assunto da revista: MEDICINA TROPICAL Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil