Your browser doesn't support javascript.
loading
Locoregional control using highly conformal flank target volumes and volumetric-modulated arc therapy in pediatric renal tumors: Results from the Dutch national cohort.
Mul, Joeri; van Grotel, Martine; Seravalli, Enrica; Bosman, Mirjam E; van Tinteren, Harm; Roy, Prakriti; Dávila Fajardo, Raquel; Tytgat, Godelieve A M; Mavinkurve-Groothuis, Annelies M C; van de Ven, Cornelis P; Wijnen, Marc H W A; de Krijger, Ronald R; Littooij, Annemieke S; van den Heuvel-Eibrink, Marry M; Janssens, Geert O.
Afiliação
  • Mul J; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands; Department of Radiation Oncology, University Medical Center Utrecht, The Netherlands.
  • van Grotel M; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.
  • Seravalli E; Department of Radiation Oncology, University Medical Center Utrecht, The Netherlands.
  • Bosman ME; Department of Radiation Oncology, University Medical Center Utrecht, The Netherlands.
  • van Tinteren H; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.
  • Roy P; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.
  • Dávila Fajardo R; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands; Department of Radiation Oncology, University Medical Center Utrecht, The Netherlands.
  • Tytgat GAM; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.
  • Mavinkurve-Groothuis AMC; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.
  • van de Ven CP; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.
  • Wijnen MHWA; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.
  • de Krijger RR; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands; Department of Pathology, University Medical Center Utrecht, The Netherlands.
  • Littooij AS; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands; Department of Radiology, University Medical Center Utrecht, The Netherlands.
  • van den Heuvel-Eibrink MM; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.
  • Janssens GO; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands; Department of Radiation Oncology, University Medical Center Utrecht, The Netherlands. Electronic address: G.O.R.Janssens@umcutrecht.nl.
Radiother Oncol ; 159: 249-254, 2021 06.
Article em En | MEDLINE | ID: mdl-33845042
BACKGROUND AND PURPOSE: In pediatric renal tumors, conventional two opposing photon beams have been used to cover the postoperative flank target volume for decades. This single center study describes the locoregional outcome using highly conformal flank target volumes adjusted for postoperative changes and intra-fraction motion combined with Volumetric-Modulated Arc Therapy (VMAT). MATERIALS AND METHODS: Between 01-2015 and 12-2019, 36/161 newly diagnosed patients with renal tumors underwent flank only irradiation (n = 30) or flank + whole lung irradiation (n = 6) using highly conformal target volumes in line with the SIOP-RTSG consensus statement. VMAT consisted of full-arc 10MV photon beams optimized for constraints of the organs at risk. In case of locoregional relapses, image co-registration and dose reconstruction was performed. Each relapse was classified as either 'infield' (V95%relapse: ≥99.0%), 'marginal' (V95%relapse: 20.0-98.9%) or 'outfield' (V95%relapse: 0-19.9%). RESULTS: At a median follow-up from diagnosis of 3.1 years (range:0.4-5.7), the estimated 2-year Locoregional Control Rate, Disease-Free Interval and Overall Survival were 94%, 91% and 94%, respectively. Locoregional relapse was observed in two patients. One patient had a combined tumor bed and regional recurrence, classified as infield (V95%relapse: 100%) and outfield (V95%relapse: 1.2%). The second patient had a regional relapse in the inferior vena cava classified as marginal recurrence (V95%relapse: 93%). Relapses would not have been adequately covered by conventional beams. CONCLUSIONS: This single center analysis provides encouraging evidence that excellent locoregional control can be obtained by using highly conformal flank target volumes with VMAT in pediatric renal tumors. The safety of this approach will be validated in a prospective multicenter study.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radioterapia de Intensidade Modulada / Neoplasias Renais Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Child / Humans Idioma: En Revista: Radiother Oncol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radioterapia de Intensidade Modulada / Neoplasias Renais Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Child / Humans Idioma: En Revista: Radiother Oncol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda