Highly cross-linked polyethylene in primary total knee arthroplasty is associated with a lower rate of revision for aseptic loosening: a meta-analysis of 962,467 cases.
Gkiatas, Ioannis; Karasavvidis, Theofilos; Sharma, Abhinav K; Xiang, William; Malahias, Michael-Alexander; Chalmers, Brian P; Sculco, Peter K.
Afiliação
  • Gkiatas I; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, 10022, USA. gkiatasi@hss.edu.
  • Karasavvidis T; School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece.
  • Sharma AK; Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, 10022, USA.
  • Xiang W; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, 10022, USA.
  • Malahias MA; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, 10022, USA.
  • Chalmers BP; Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, 10022, USA.
  • Sculco PK; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, 10022, USA.
Arch Orthop Trauma Surg ; 142(6): 1177-1184, 2022 Jun.
Article em En | MEDLINE | ID: mdl-33847797
ABSTRACT

BACKGROUND:

The evolution in total knee arthroplasty (TKA) includes the highly cross-linked polyethylene (HXLPE) which has been reported as an effective manner to reduce the wear of the polyethylene and the osteolysis. The purpose of the present study is to synthesize the results of comparative studies between HXLPE and conventional polyethylenes and determine their effect in primary TKA.

METHODS:

The US National Library of Medicine (PubMed/MEDLINE) and the Cochrane Database of Systematic Reviews were queried for publications utilizing the following keywords "cross-linked", "polyethylene", "HXLPE", "conventional", "total knee arthroplasty", "TKA", "total knee replacement" and "TKR" combined with Boolean operators AND and OR.

RESULTS:

Ten studies met the inclusion criteria and were included in the present meta-analysis with 962,467 patients. No significant difference was found regarding the revision rate for any reason between the patients who received HXLPE and those with conventional liner (OR 0.67; 95% CI 0.39-1.18; I2 97.7%). In addition, there was no difference regarding the radiolucent lines between the two types of liners (OR 0.54; 95% CI 0.20-1.49; I2 69.4%). However, with data coming from seven studies enrolling a total of 411,543 patients, it was demonstrated that patients who received HXLPE were less likely to be revised due to aseptic loosening compared to the patients with conventional liners (OR 0.35; 95% CI 0.31-0.39; I2 0.0%).

CONCLUSION:

The present meta-analysis showed that regarding the overall revision rate and radiographic outcomes there was no significant difference between the two types of liners. On the other hand, the significantly less revision rate due to loosening supports the routine continued use of HXLPE in primary TKA.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Artroplastia do Joelho / Prótese de Quadril Tipo de estudo: Risk_factors_studies / Systematic_reviews Limite: Humans Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Artroplastia do Joelho / Prótese de Quadril Tipo de estudo: Risk_factors_studies / Systematic_reviews Limite: Humans Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos