Your browser doesn't support javascript.
loading
Short-wavelength ultraviolet dosimeters based on DNA nanostructure-modified graphene field-effect transistors.
Ai, Zhaolin; Wang, Liqian; Guo, Qianying; Kong, Derong; Wu, Yungen; Liu, Yunqi; Wei, Dacheng.
Afiliação
  • Ai Z; State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China. weidc@fudan.edu.cn and Institute of Molecular Materials and Devices, Fudan University, Shanghai 200433, China.
  • Wang L; State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China. weidc@fudan.edu.cn and Institute of Molecular Materials and Devices, Fudan University, Shanghai 200433, China.
  • Guo Q; State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China. weidc@fudan.edu.cn and Institute of Molecular Materials and Devices, Fudan University, Shanghai 200433, China.
  • Kong D; State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China. weidc@fudan.edu.cn and Institute of Molecular Materials and Devices, Fudan University, Shanghai 200433, China.
  • Wu Y; State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China. weidc@fudan.edu.cn and Institute of Molecular Materials and Devices, Fudan University, Shanghai 200433, China.
  • Liu Y; Institute of Molecular Materials and Devices, Fudan University, Shanghai 200433, China.
  • Wei D; State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China. weidc@fudan.edu.cn and Institute of Molecular Materials and Devices, Fudan University, Shanghai 200433, China.
Chem Commun (Camb) ; 57(41): 5071-5074, 2021 May 20.
Article em En | MEDLINE | ID: mdl-33889878
ABSTRACT
Direct and sensitive short-wavelength ultraviolet (UVC) dosimeters could provide a safer disinfection environment against viruses. We developed direct, quantitative, specific and highly sensitive UVC dosimeters based on DNA nanostructure-modified graphene field-effect transistors. Detectable doses of the dosimeters range from 0.005 to 6 kJ m-2 and such dosimeters have at least 5 times better sensitivity than the current direct UV dosimeters.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Raios Ultravioleta / DNA / Nanoestruturas / Dosímetros de Radiação / Grafite Idioma: En Revista: Chem Commun (Camb) Assunto da revista: QUIMICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Raios Ultravioleta / DNA / Nanoestruturas / Dosímetros de Radiação / Grafite Idioma: En Revista: Chem Commun (Camb) Assunto da revista: QUIMICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China