Batch injection analysis with amperometric detection for fluoroquinolone determination in urine, pharmaceutical formulations, and milk samples using a reduced graphene oxide-modified glassy carbon electrode.
de Faria, Lucas Vinícius; de Farias, Davi Marques; Lisboa, Thalles Pedrosa; Matos, Maria Auxiliadora Costa; Munoz, Rodrigo Alejandro Abarza; Matos, Renato Camargo.
Afiliação
  • de Faria LV; NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil. viniciuslucas82@yahoo.com.br.
  • de Farias DM; NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil.
  • Lisboa TP; NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil.
  • Matos MAC; NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil.
  • Munoz RAA; NUPE (Núcleo de Pesquisas em Eletroanalítica), Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, MG, 38400-902, Brazil.
  • Matos RC; NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil. renato.matos@ufjf.edu.br.
Anal Bioanal Chem ; 414(18): 5309-5318, 2022 Jul.
Article em En | MEDLINE | ID: mdl-33890118
ABSTRACT
In this work, the batch injection analysis system with amperometric detection using reduced graphene oxide as a modifier of glassy carbon electrode (GCE) was investigated for the simple, fast, and sensitive monitoring of levofloxacin (LEVO) and ciprofloxacin (CIPRO) in samples of pharmaceutical formulations, synthetic urine, and milk (low- and high-fat content). LEVO and CIPRO were quantified in seven samples using amperometric measurements at +1.10 V vs Ag/AgCl, KCl(sat). The developed methods showed excellent analytical performance with limits of detection of 0.30 and 0.16 µmol L-1, linear range from 3.0 to 50 µmol L-1 and 1.0 to 50 µmol L-1, relative standard deviation below 9.7 and 3.1%, and recovery ranges ranging from 80 to 107% and from 78 to 109% for LEVO and CIPRO, respectively. In addition, the minimum sample preparation (simple dilution) combined with a high analytical frequency (130 to 180 analyses per hour) can be highlighted. Thus, the methods are promising for implementation in routine analysis and quality control to different samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carbono / Fluoroquinolonas Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carbono / Fluoroquinolonas Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil