Your browser doesn't support javascript.
loading
3D ultrasound guided navigation system with hybrid image fusion.
Iommi, David; Valladares, Alejandra; Figl, Michael; Grahovac, Marko; Fichtinger, Gabor; Hummel, Johann.
Afiliação
  • Iommi D; Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Spitalgasse 23, Vienna, 1090, Austria.
  • Valladares A; Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Spitalgasse 23, Vienna, 1090, Austria.
  • Figl M; Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Spitalgasse 23, Vienna, 1090, Austria.
  • Grahovac M; Division of Nuclear Medicine, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria.
  • Fichtinger G; Queen's University, School of Computing, 25 Union St, 557 Goodwin Hall, Kingston, ON, K7L 3N6, Canada.
  • Hummel J; Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Spitalgasse 23, Vienna, 1090, Austria. johann.hummel@meduniwien.ac.at.
Sci Rep ; 11(1): 8838, 2021 04 23.
Article em En | MEDLINE | ID: mdl-33893323
ABSTRACT
A prototype of a navigation system to fuse two image modalities is presented. The standard inter-modality registration is replaced with a tracker-based image registration of calibrated imaging devices. Intra-procedure transrectal US (TRUS) images were merged with pre-procedure magnetic resonance (MR) images for prostate biopsy. The registration between MR and TRUS images was performed by an additional abdominal 3D-US (ab-3D-US), which enables replacing the inter-modal MR/TRUS registration by an intra-modal ab-3D-US/3D-TRUS registration. Calibration procedures were carried out using an optical tracking system (OTS) for the pre-procedure image fusion of the ab-3D-US with the MR. Inter-modal ab-3D-US/MR image fusion was evaluated using a multi-cone phantom for the target registration error (TRE) and a prostate phantom for the Dice score and the Hausdorff distance of lesions . Finally, the pre-procedure ab- 3D-US was registered with the TRUS images and the errors for the transformation from the MR to the TRUS were determined. The TRE of the ab-3D-US/MR image registration was 1.81 mm. The Dice-score and the Hausdorff distance for ab-3D-US and MR were found to be 0.67 and 3.19 mm. The Dice score and the Hausdorff distance for TRUS and MR were 0.67 and 3.18 mm. The hybrid navigation system showed sufficient accuracy for fusion guided biopsy procedures with prostate phantoms. The system might provide intra-procedure fusion for most US-guided biopsy and ablation interventions.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Áustria

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Áustria